Fantom Vacuum FM744H AIR Driven Turbo Brush, Using the Unit With Air Driven Turbo Brush

Page 12

AIR DRIVEN TURBO BRUSH

Using the Unit With Air Driven Turbo Brush

The efficiency of your Air Driven turbo brush depends on the bristle brush rotating at high speed. Strong air suction is needed to accomplish this. In order to ensure that maximum air suction is maintained, please read the following instructions:

1.Always empty the dust cup container frequently during use. Follow instructions on dust container.

2.Ensur that the rotating brush is kept free of hair and string which may accumulate and decrease brush performance.

3.Keep Air Driven Turbo Brush turbine free of dirt and foreign matter. (see illustration below for cleaning instructions.)

Using The Unit With Air Driven Turbo Brush

Your Air Driven turbo Brush may be used with either the extension tubes or the flexible hose.

Cleaning Air Driven Turbo Brush

Locking Latch

Tilt

Upwards

Turbine

From time to time, the turbine of your Turbo Brush will require cleaning. To do this:

1.Remove the turbo brush from the hose or extension tube.

2.Slide locking latch forward then tilt the top housing of the brush upwards. The top housing is

hinged and will tilt up approximately 45 only.

3.There may be some dust, lint, hair, etc on the turbine wheel. Remove as much of this as possible.

4.You may also use the unit's hose with crevice tool attached and use the vacuum to remove any additional debris from the turbine.

5.Ensure that the turbine wheel moves freely by rotating it with your finger. If the turbine does not rotate, call FANTOM Customer Service for help.

6.Once clean, close the top cover of the Turbo Brush and slide the locking latch toward the rear of the brush to lock.

IMPORTANT

TURBO BRUSH INSTRUCTIONS

The efficiency of your Air Driven Turbo Brush depends on the bristle brush rotating at high speed. Strong air suction is needed to accomplish this.

In order to ensure that maximum air suction is maintained, please read the following instructions:

1)Empty the Dust Container frequently during use. Follow instructions for dust container.

2)Ensure that the rotating brush is kept clear of hair and string.

3)Inspect the turbine regularly to ensure that the air passage is free of dirt and debris.

10

Image 12
Contents FM744H Page Important Safety Instructions Read ALL Instructions Before Using this Vacuum CleanerGrounding Instructions Names of Each Part Front RearPreparations Before USE Attaching the handleInserting the Power Cord Plug Prep ARA Tions Before USEDI NG T HE P OW ER C or D L E a S in G T HE P OW E R C or DUsing the Vacuum Cleaner ON/OFF SwitchAdjusting the Handle Height Adjustment Lever Edge CleaningRUG/FLOOR Toolsselector Using the Attachments Upholstery tool & Dusting brushHose Attachment Using the Unit With Air Driven Turbo Brush AIR Driven Turbo BrushPower cord from the wall outlet before cleaning Emptying the Dust CompartmentCleaning the Filters Cleaning UtensilClearing Blockages and Cleaning the Agitator Assembly Replacement Instructions Replacing the Headlight LampReplacing the Flat Belt Removing the Bottom Plate Reattaching the Bottom PlateCleaning the SUB-FILTER Replacing the FilterTroubleshooting Problem Cause RemedyFive 5 Year Limited Warranty