Daewoo DMB-3003LH owner manual To SET Heat Mode, To Select the FAN Direction

Page 13

DMB-3003LH 2003.3.4 9:57 AM 페이지12

TO SET HEAT MODE

To set the unit to heat the room to a desired temperature, follow the procedures below:

1.Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and “ON” will light in the

remote display.

3. Using the TEMP. or buttons, set the desired temperature. The desired temperature can be changed up to 32°C and

down to 18°C.

2. Press the MODE button until the Heat indicator appears in the display.

In the heat mode, the fan direction

or is further downward than that in the cool mode for the good

circulation.

4. To select the fan speed, press the FAN SPEED button until the desired speed appears in the display (see below).

NOTE:

When the heating orperation is started, hot air delivery might be delayed due to warm up period.

FAN SPEEDS

“AUTO” The fan will automatically select the fan speed.

” The fan will operate on low speed.

” The fan will operate on medium speed.

” The fan will operate on high speed. “NATURAL” The fan will randomly cycle through the

speeds simulating a cool breeze.

TO SELECT THE FAN DIRECTION

Regardless of the mode the unit is set for, the fan direction can be changed so it moves up and down. Follow procedures below to set fan direction.

1.Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and “ON” will light in the

remote display.

2. Press the MODE button to select the desired mode.

3.Press the FAN DIR. button to select the fan direction. See chart below

for detailed information on each of

 

the three settings.

FAN DIR.

FAN DIR. First Press

Second

Press

The air will flow up and down.

Normal air direction.

12

Image 13
Contents DMB-3003LH Important Notes Safety InstructionsRoom AIR Conditioner Instruction Contents Indoor Unit Capacity Cooling W Heating W 3220 3500 ConfigurationService Valve Service CoverLocation of Controls Indoor UnitIndoor Unit Display Indoor Unit Display Switch PanelRemote Display Remote ControllerSetting the Unit for Remote Operation Connecting the AC CordThree Minute Compressor Delay OperationCelsius to Fahrenheit Conversion Chart HOW to Install BatteriesOperation mode of the remote controller To SET Quick Mode To SET Auto ModeTo SET Cool Mode To SET Dehumidifier Mode To SET only FAN ModeTo Select the FAN Direction To SET Heat ModeTo SET OFF Timer Mode To SET on Timer ModeTo SET TURBO/MILD Mode To SET Sleep ModeTo Cancel Sleep Mode Emergency OperationOverview Installation DiagramAC Connection Diagram Cleaning the Indoor Cover CHANGING/CLEANING the AIR FiltersAfter the Season Care and MaintenanceSymptoms Possible Cause Possible Solutions Troubleshooting Guide