| TROUBLESHOOTING |
CONDITION |
| POSSIBLE CAUSE(S) |
| POSSIBLE SOLUTIONS(S) |
|
|
|
| |
NO SOUND FROM ALL CHANNELS | • | AC power unplugged | • Check AC cable, connection, and outlet | |
| • Power not switched on | • | Disengage Tape Monitor | |
| • | Outlet is unpowered |
|
|
| • | Tape Monitor is engaged |
|
|
|
|
|
|
|
NO SOUND FROM SOME CHANNELS | • | Faulty/missing cables | • | Check cables |
| • <Speaker Settings> channel (s) set to "None" | • Check <Speaker Settings> menu | ||
| • | • | Check power amp, cabling, and speakers | |
|
|
|
| |
NO SOUND FROM SURROUND | • | No surround listening mode is engaged | • Select appropriate listening mode | |
CHANNELS | • | • Correct <Speakers Settings> or | ||
|
| <Speaker Settings> menu |
| <Channel Levels> settings |
| • |
|
| |
|
| <Channel Levels> menu |
|
|
|
|
|
|
|
NO SOUND FROM SUBWOOFER | • | Subwoofer is off, unpowered, | • | |
|
| or improperly connected |
| AC outlet, or check connections |
| • Subwoofer set to "OFF" on | • Correct <Speakers Settings> or | ||
|
| <Speaker Settings> menu |
| <Levels setup> settings |
| • | Sub level set too low on |
|
|
|
| <Channel Levels> menu |
|
|
|
|
|
| |
NO SOUND FROM CENTER CHANNEL | • | Source is a 2/0 (etc.) Dolby Digital or | • Play a known | |
|
| DTS recording without center channel; |
| select Dolby Pro Logic or Mono mode |
| • Center set to "OFF" on | • Correct <Speakers Settings> or | ||
|
| <Speaker Settings> menu |
| <Channel Levels> settings |
| • | Center level set too low on |
|
|
|
| <Channel Levels> menu |
|
|
|
|
|
|
|
NO DOLBY DIGITAL/DTS | • | Source's digital output is not connected to | • | Check connections |
|
| a T 752 digital input | • Check source component setup | |
| • Source component not configured for multi |
|
| |
|
| channel digital output |
|
|
|
|
|
|
|
T 752 DOES NOT RESPOND | • | Batteries are flat or incorrectly inserted | • | Check batteries |
TO HTR 2 REMOTE | • | IR transmitter window on remote, o | • | Check IR windows and ensure clear |
|
| IR receiver window on T 752 is obstructed |
| |
| • T 752 front panel is in very bright sunlight | • | Reduce sunlight/room lighting | |
|
| or ambient light |
|
|
|
|
|
| |
T 752 DOES NOT RESPOND | • | Microprocessor error | • | |
FROM THE AC OUTLET | • | T752 may have over heated |
| Power key and unplug it from the AC outlet |
TO | • | 12V TRIGGER IN/OUT is set to AUTO or | • Wait five minutes, | |
|
| “on” position |
| power up |
|
|
| • Switch to OFF position | |
|
|
|
|
|