Control the Environment

The System controls the room environment by engaging one of four modes: Cool, Dehumidify, Reheat, or Humidify. These modes may work differently depending on the options and equipment installed in your Modules.

The environmental controls are set when your System is installed. Changing settings described in this section after the system has been commissioned may result in improper operation.

How the modes work

Cool. When the cool mode uses a Chilled Water coil, the output is determined by the difference between the setpoint and the measured air temperature (control temperature) of each of the Modules in the System (if more than one Module is present). The control temperature can be the average return sensor value, the average remote sensor value, or the maximum remote sensor value, depending on the System settings (Path: Main > Setup > System > System Setup > System Config > Sensor Setup)

See “Sensor setup” on page 9 to choose the source of the temperature value which the Module uses to calculate demand.

The Proportional plus Integral plus Derivative (PID) control loop calculates the output as demand increases and opens the valve controlling the flow of coolant into the coil. The PID adjusts the output as required to maintain the temperature at the setpoint.

See “PID controls” on page 23 for a description of the PID controls and instructions on tuning the fluid coil PID loop.

Reheat (Electric SCR and Modulating Hot Water). The SCR (silicon-controlled rectifier) electric reheat function is controlled by the reheat PID controller. The PID controller adjusts the output as required to maintain the temperature at the setpoint.

See “PID controls” on page 23 for a description of the PID controls and instructions on tuning the reheat PID loop.

Reheat (Hot Gas, Steam, Hot Water On/Off). The output of the hot gas, steam, and hot water on/off reheat options is determined by the difference between the setpoint and control temperature of the Module. When the control temperature at the Module reaches the setpoint minus the deadband, the reheat mode activates until the control temperature rises to the setpoint.

See “Deadbands” on page 22 for acceptable reheat deadband values.

20

NetworkAIR IR Operation, Maintenance, and Troubleshooting

Image 26
Contents NetworkAIR IR Precision Air Conditioner Page Contents Set Up Alarms Network Management Card Maintenance Operation Display InterfaceUsing the Display Scrolling status screensMain menu screen Navigating the interfaceStart the System Password entryChange settings Stop the System Set Up System Configuration System OptionsOperation Set Up System Configuration System Delays Sensor setup Building managementFluid-Coil Type Applicable Settings Options for Fluid-Cooled ModulesValve Types Actuator TypesCoil Fluid Temp Activation Threshold and Deadband Set Up Contacts and Relays Input contactsOutput relays Map Description/FunctionOperation Set Up Contacts and Relays Alarm detectors Set Up Module ConfigurationConfigure Module Calibrate airflow automatically Set Up Module ControlCalibrate airflow manually Set up Humidifier Reset variable frequency driveReset humidifier Reset compressors Control the Environment How the modes workSetpoints Essential Functions DeadbandsModes PID controls How to tune the PIDs Loop Behavior PID Tuning CorrectionHumidification sensitivity Humidity alarms Set Up AlarmsTemperature alarms Coil fluid thresholds Alarm delayMaint intervals Set Up Group Group configGroup settings Sys failure eventsOperation Set Up Group Temperature & pressure units Set Up the DisplayPassword & Time-out Date and timeAdjust display How to update the firmwareReset to defaults Product dataSet Up Network Configuration Network configView Status Readings Module statusSystem status View Log Group statusView Event Log View active alarms Respond to AlarmsMajor or minor alarm LEDs Control beeperClear active alarms Reset sys failureAlarm messages and suggested actions Displayed Alarm Message Action RequiredDisplayed Alarm Message Action Required Check that the # Systems setting Path Main Setup Group Group Module Module in which the alarm occurred Module Control Displayed Alarm Message Action Required Displayed Alarm Message Action Required Page Quick Configuration OverviewBootp & Dhcp configuration TCP/IP configuration methodsAPC Device IP Configuration Wizard Network Management Card Quick Configuration Option 43 = 01 04 31 41 50 Local access to the control console Remote access to the control console Control consoleNetwork Management Card Quick Configuration Telnet/SSH How to Access a Configured UnitWeb interface Snmp FTP/SCP How to Recover From a Lost Password How to Upgrade Firmware Upgrade the AOS. For example Page Monthly Preventive Maintenance EnvironmentElectrical CleanlinessMechanical Quarterly Preventive Maintenance Record the amperages for the following componentsFunctional tests Semi-Annual Preventive Maintenance Page Troubleshooting Troubleshooting Semi-Annual Preventive Maintenance Problem Possible Cause Corrective Action Page APC product covered Limited Product Warranty for APC ProductsTerms of warranty Exclusions Assignment of warrantiesDrawings, descriptions Limited Product Warranty for APC Products Labor Warranty ProceduresClaims Parts Page Page APC Worldwide Customer Support

Central Air Conditioning System specifications

American Power Conversion (APC) is renowned for delivering innovative solutions in the realm of power management, but its contributions don't stop there. The company has also made significant advancements in central air conditioning systems. Featuring cutting-edge technologies and energy-efficient designs, their HVAC systems are tailored to meet modern needs while ensuring comfort and sustainability.

One of the standout features of APC central air conditioning systems is their variable speed compressor technology. This advanced system operates at different speeds rather than just cycling on and off. By adjusting the compressor speed to match the cooling demand, these systems optimize energy consumption, leading to lower electricity bills and extended equipment lifespan.

APC's systems also incorporate smart thermostat capabilities, allowing homeowners to monitor and control their air conditioning remotely. Through a mobile app, users can adjust temperature settings, create schedules, and receive maintenance alerts, all of which enhance convenience and efficiency. Furthermore, these smart thermostats can learn user habits over time, automatically adjusting temperature settings to maximize comfort and savings.

Another key characteristic of APC central air conditioning systems is their commitment to eco-friendly refrigerants. Utilizing low global warming potential (GWP) refrigerants, these systems minimize the environmental impact while maintaining high-performance standards. With energy efficiency ratings that often exceed industry benchmarks, APC systems contribute to reduced greenhouse gas emissions and help homeowners adopt sustainable practices.

The design of APC air conditioning units is also noteworthy. They are constructed with durable materials that withstand various weather conditions, ensuring reliability during the hottest months. Additionally, the streamlined design of these systems enhances aesthetic appeal, making them a suitable choice for modern homes.

In conclusion, the American Power Conversion central air conditioning system exemplifies the synergy of innovative technology, energy efficiency, and user-friendly features. With variable speed compressors, smart controls, eco-friendly refrigerants, and robust construction, APC provides homeowners with a dependable and sustainable climate control solution. As demand for energy-efficient products continues to grow, APC is poised to lead the way in intelligent air conditioning solutions that prioritize both comfort and environmental responsibility.