Heatcraft Refrigeration Products none Refrigerant Charge. Lbs. R-22 for Flooded Condenser

Page 12

Table 7. Refrigerant Charge for Fan Cycling plus Flooded Condenser (lbs. R-22)

Model*

Summer

Charge

 

25° TD

 

 

20° TD

 

 

15° TD

 

 

10° TD

 

40°F

20°F

0°F

-20°F

40°F

20°F

0°F

-20°F

40°F

20°F

0°F

-20°F

40°F

20°F

0°F

-20°F

1

8

7

8

9

9

8

9

10

10

9

10

11

11

13

12

12

12

2

10

9

12

13

14

11

13

14

15

13

14

15

16

17

18

17

18

3

10

1

6

8

10

4

8

10

11

7

10

12

13

10

13

14

14

4

15

2

9

12

15

7

12

15

17

12

16

18

19

17

19

21

22

5

29

4

17

24

29

14

24

30

34

24

31

36

39

33

38

41

43

6

22

0

3

10

15

0

10

16

20

0

17

22

25

0

24

27

29

7

30

0

4

13

20

0

12

20

26

0

21

27

32

0

29

34

38

8

51

0

0

8

22

0

6

23

35

0

22

38

48

0

37

52

61

9

70

0

0

11

29

0

8

31

46

0

29

51

63

0

49

71

80

10

64

0

0

0

15

0

0

17

33

0

0

39

52

0

0

60

70

11

86

0

0

0

19

0

0

22

44

0

0

50

69

0

0

78

93

12

102

0

0

0

6

0

0

8

37

0

0

37

69

0

0

66

100

13

118

0

0

0

0

0

0

0

29

0

0

0

69

0

0

0

108

14

19

3

12

17

20

9

17

21

23

15

22

25

26

21

27

29

29

15

29

4

17

24

29

13

24

30

34

22

31

36

39

31

38

41

43

16

40

5

22

32

38

17

31

39

44

29

40

46

50

41

49

53

56

17

44

0

5

20

31

0

18

31

40

0

31

42

49

0

44

53

59

18

58

0

7

27

42

0

25

42

54

0

43

57

66

0

61

71

79

19

104

0

0

17

44

0

12

47

69

0

43

77

95

0

74

107

119

20

140

0

0

22

57

0

16

62

91

0

57

102

125

0

99

141

157

21

125

0

0

0

30

0

0

34

67

0

0

77

105

0

0

120

141

22

172

0

0

0

39

0

0

44

88

0

0

100

137

0

0

156

186

23

201

0

0

0

11

0

0

16

74

0

0

74

137

0

0

132

200

24

236

0

0

0

0

0

0

0

57

0

0

0

135

0

0

0

213

* See Model Cross Reference Table #10..

Table 8. Refrigerant Charge. Lbs. R-22 for Flooded Condenser

Model*

Refrigerant R-22

Charge

for summer

Operation, Lbs.

Additional Refrigerant R-22 Charge Required for Flooded Condenser Operation Lbs. For

20°F TD Minimum Ambient at Condenser

+60

+40

+20

+0

-20

1

8

7

10

11

11

11

2

10

10

13

15

15

16

3

10

10

13

14

15

15

4

15

15

19

21

22

23

5

29

30

39

43

45

47

6

22

22

29

32

34

35

7

30

29

38

42

44

46

8

51

50

66

74

77

80

9

70

66

87

96

100

105

10

64

62

83

92

95

99

11

86

83

110

122

127

132

12

102

100

132

147

153

159

13

118

117

155

172

179

186

14

19

20

27

29

31

32

15

29

30

39

44

46

47

16

40

39

51

57

59

62

17

44

44

58

64

67

70

18

58

59

78

86

90

94

19

104

99

131

146

152

158

20

140

131

174

193

201

209

21

125

126

168

186

194

201

22

172

165

219

243

253

263

23

201

201

267

296

308

320

24

236

233

310

343

357

372

* See Model Cross Reference Table #10..

12

Image 12
Contents Air-Cooled Condensers Installation Operation Guide System Warranty InstallationInspection Sound VibrationDrawing 1. Rigging Instructions Space and Location Requirements Walls or ObstructionsMultiple Units Units in PitsInstallation, Refrigerant Piping Typical ArrangementsElectrical Wiring Condensing Temperature Correction FactorDischarge Lines Tons of RefrigerationPage Fan Cycling Discharge Gas PulsationWinter Operation Head Pressure Control Fan Cycling Head Pressure Controls Flooding Head Pressure ControlsVariable Speed Splitting ControlsMechanical Fan Cycling Thermostat Settings Minimum Ambient for Fan CyclingElectronic Fan Cycling Thermostat Settings Pressure ChartRefrigerant Charge. Lbs. R-22 for Flooded Condenser Model Summer ChargeMaintenance Cleaning InstructionsFlooded Charge Temperature Difference Factor Model Cross ReferenceInterLink Condenser Parts List In-Warranty Return Material ProcedureParts by InterLink Fan Motor PartSpeed Adjustment Characteristics External Control SignalSeries Motors with Integrated Variable Speed Be sure that the unit is isolatedReverse acting or direct acting mode of operation Head Pressure SetpointMinimum Output Throttling rangeMaster/Slave Configuration Protective FeaturesPhase failure EC Motor WiringFAN 1 Header FAN FAN Motor Identification Installation Check List

none specifications

Heatcraft Refrigeration Products is a recognized leader in providing innovative and energy-efficient cooling solutions. The company specializes in manufacturing an extensive array of refrigeration systems designed to meet the demands of various commercial applications. With a strong commitment to quality and sustainability, Heatcraft integrates advanced engineering principles in every product, ensuring reliability and performance.

One of the standout features of Heatcraft products is their versatility. The company offers a wide range of refrigeration units, including condensing units, evaporators, and packaged systems, designed to accommodate different operational requirements. Whether it's for supermarkets, restaurants, or cold storage facilities, Heatcraft provides solutions that ensure optimal temperature control and energy efficiency.

Heatcraft places a significant emphasis on energy efficiency, developing technologies that help reduce operational costs while minimizing the environmental impact. Their products often incorporate advanced compressor systems, environmentally friendly refrigerants, and intelligent controls that adjust performance based on real-time conditions. This focus on energy-saving innovations not only benefits the planet but also boosts the bottom line for businesses that rely on refrigeration.

Furthermore, Heatcraft is known for its user-friendly design and ease of installation. Their systems are engineered for straightforward setup and maintenance, allowing businesses to minimize downtime and ensure seamless operations. This design philosophy extends to the company’s extensive catalog of components and accessories, providing customers with a comprehensive suite of options tailored to their specific needs.

Heatcraft also prioritizes customer support and service, offering resources and training for technicians to enhance their expertise in handling refrigeration systems. With a strong distribution network and support from knowledgeable representatives, customers can be assured that help is always accessible.

In addition, Heatcraft values innovation and continuously invests in research and development to stay ahead of industry trends. This dedication to advancement ensures that their products not only conform to current regulations but also anticipate future needs in the refrigeration sector.

Overall, Heatcraft Refrigeration Products exemplifies excellence in design, efficiency, and support, establishing itself as a trusted partner in the HVAC and refrigeration industries. Their commitment to quality and sustainability positions them as a frontrunner, meeting the evolving demands of a diverse market.