Heatmaster 100 N, HM 60 N, 150 JUMBO, 70 N manual C53, Balanced flue boiler connection type C

Page 10

Balanced flue boiler connection type: C

C13: concentric horizontal connection

C33: concentric vetical connection

C53: parallel chimney connection

C63: concentric vertical connection without terminal (only in Germany and Luxembourg).

C33

 

 

 

 

 

 

 

min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120

 

 

 

 

150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C13

2 m min.

Maximum length concentric : 6 metres

Maximum length parallel : 12 metres

Note: a 90 degree bend = 1 metre equivalent length

INSTALLATION

C53

A condensation drain outlet must be fitted close to the boiler to prevent condensation products from the chimney running into the boiler.

To avoid condensation water running out of the terminal, all horizontal flue runs must fall back towards the boiler.

9

Image 10
Contents HeatMaster Index IntroductionDescription Construction FeaturesOperating Principle Burner chamber plate Safety features of the HeatMaster 150 Jumbo Maximum Operating Conditions Technical SpecificationGeneral Features Burner Chamber PlateDimensions 562 Boiler Room InstallationChimney Connections C53 Balanced flue boiler connection type CHOT Water Connections Heating Connection OIL Supply Connections ACV BM BurnersSafety Wiring DiagramPower supply Electrical ConnectionsElectrical connection HeatMaster 150 Jumbo Commissioning Filling the HOT Water and Heating CircuitsACV BG 2000-S Premix GAS Burners Burner FeaturesACV BG 2000-S premix gas burners dimensions DescriptionL1 N T1 T2 S3 B4 Electrical connectionsACV premix gas burner BG 2000-S/60 and BG 2000-S/70 HM 60 N HM 70 N HM 100 N HM 150 Jumbo HeatMaster 60, 70 and 100 Gas burner features BGGas category M3/hBM oil burners dimensions FeaturesOil burner specification and perfomances ACV BM 101 and BM 151 OIL BurnersService Intervals MaintenanceServicing the Boiler Draining the Boiler Servicing the Safety DevicesServicing the Burner Spare PartsUser Guide Using the BoilerUnderstanding the control panel Safety Valves Heating system pressureResetting the BG 2000-S Premix GAS Burner Resetting the Pressure JET OIL or GAS BurnerBurner Troubleshooting Service Record Date serviced Flue gas T Remarks Service Record Service Record World.com

150 JUMBO, 100 N, HM 60 N, 70 N specifications

The Heatmaster series, including the Heatmaster 150 JUMBO, 70 N, HM 60 N, and 100 N, represents a breakthrough in heating technology, designed to meet diverse heating needs with efficiency and reliability. Each model in this series offers unique features tailored for various applications, making the Heatmaster brand a prominent choice in the heating sector.

The Heatmaster 150 JUMBO stands out with its high-capacity output, capable of heating larger spaces effectively. It is equipped with an advanced burner technology that ensures optimal combustion efficiency, reducing fuel consumption and emissions. The model includes a user-friendly control panel with digital displays for temperature settings and operational statuses, allowing users to maintain precise heating levels effortlessly.

The Heatmaster 70 N is engineered for medium-sized areas, offering a perfect balance of power and portability. This unit is designed with an integrated heat exchanger that maximizes heat transfer while minimizing energy losses. Additionally, it features a robust safety system, including automatic shut-off mechanisms and thermal protection, ensuring both user safety and device longevity.

The HM 60 N model focuses on compact design without compromising performance. Its lightweight structure facilitates easy transport and installation, making it ideal for temporary heating solutions such as construction sites and event spaces. The HM 60 N utilizes a dual-fuel capability, allowing it to operate on either gas or electricity, thus providing flexibility based on the availability of resources.

Meanwhile, the Heatmaster 100 N model brings together enhanced durability and high efficiency, catering to various commercial and industrial applications. This model features an advanced insulation system that minimizes heat loss, ensuring a consistent output over extended periods. Additionally, the Heatmaster 100 N is built with high-quality materials that withstand tough environmental conditions, making it a reliable choice for challenging settings.

All models in the Heatmaster series come equipped with smart technologies that enable remote control and monitoring capabilities, allowing users to adjust settings from their smartphones or other devices. This feature not only enhances convenience but also promotes energy savings by optimizing usage patterns.

In summary, the Heatmaster 150 JUMBO, 70 N, HM 60 N, and 100 N are engineered to provide effective heating solutions for a myriad of environments. Their innovative technologies, safety features, and efficiency make them leaders in the heating market, well-suited for both residential and commercial applications. Investing in any of the Heatmaster models guarantees peace of mind and performance, making them a worthwhile addition to any heating strategy.