MAXIMUM OPERATING CONDITIONS

Maximum service pressure (tank full of water)

-Primary circuit: 3 bar

-Secondary circuit: 10 bar

Test pressure (tank full of water)

-Primary circuit: 4.5 bar

-Secondary circuit: 13 bar

Operating temperature

- Maximum temperature: 90 °C

Water quality

Chlorures: < 150 mg/l (304)

<2000 mg/l (Duplex)

6 ph 8

TECHNICAL SPECIFICATION

BURNER CHAMBER PLATE

The burner chamber plate has 4 threads (M 10 x 20) for attaching the burner. It is protected from heat by a blanket insulation.

5xØ6.5(M8)

Ø28

Ø130

60

60

60 60

DOMESTIC HOT WATER PERFORMANCES

 

 

HM 60 N

HM 60 N

HM 70 N

HM 70 N

HM 100 N

HM 100 N

HM 150

 

 

BM 101

BG 2000-S/60

BM 101

BG 2000-S/70

BM 101

BG 2000-S/100

JUMBO

Peak delivery at 40 °C

L/10’

474

474

646

646

905

905

1504

Peak delivery at 45 °C

L/10’

378

378

543

543

777

777

1289

Peak delivery at 60 °C

L/10’

245

245

346

346

514

514

870

Peak delivery at 70 °C

L/10’

193

193

268

268

343

343

700

Peak delivery at 80 °C

L/10’

135

135

207

207

258

258

540

 

 

 

 

 

 

 

 

 

Peak delivery at 40 °C

L/60’

1942

1942

2133

2133

3172

3172

4828

Peak delivery at 45 °C

L/60’

1656

1656

1794

1794

2680

2680

4138

Peak delivery at 60 °C

L/60’

1106

1106

1219

1219

1813

1813

2864

Peak delivery at 70 °C

L/60’

681

681

971

971

1226

1226

2131

Peak delivery at 80 °C

L/60’

499

499

636

636

893

893

1362

 

 

 

 

 

 

 

 

 

Continuous delivery at 40 °C

L/h

1835

1835

1835

1835

2776

2776

3989

Continuous delivery at 45 °C

L/h

1573

1573

1573

1573

2379

2379

3419

Continuous delivery at 60 °C

L/h

1101

1101

1067

1067

1665

1665

2393

Continuous delivery at 70 °C

L/h

791

791

918

918

1104

1104

1718

Continuous delivery at 80 °C

L/h

455

455

580

580

804

804

987

 

 

 

 

 

 

 

 

 

Reheat time at 60 °C

min

9

9

16

16

13

13

17

 

 

 

 

 

 

 

 

 

GENERAL FEATURES

 

 

HM 60 N

HM 70 N

HM 100 N

HM 150

 

 

 

 

 

JUMBO

Maximum Input

kW

69.9

69.9

107.0

154.0

Maximum Output

kW

62.5

63.0

96.8

139.1

Maintenance loss at 60 °C as rated value

%

0.57

0.60

0.65

0.52

Total capacity

L

162

239

330

645

Primary circuit capacity

L

82

108

130

245

Heating connection

Ø

11/2

11/2

11/2

DN 50

Hot water connection

Ø

3/4”

1”

1”

2”

Hot water tank heat exchange surface

m2

2.46

3.14

3.95

5.30

Weight empty

Kg

220

270

320

530

Pressure drop primary circuit

mbar

54

46

83

120

 

 

 

 

 

 

5

Image 6
Contents HeatMaster Index IntroductionConstruction Features DescriptionOperating Principle Burner chamber plate Safety features of the HeatMaster 150 Jumbo Maximum Operating Conditions Technical SpecificationGeneral Features Burner Chamber PlateDimensions 562 Installation Boiler RoomChimney Connections C53 Balanced flue boiler connection type CHOT Water Connections Heating Connection OIL Supply Connections ACV BM BurnersSafety Wiring DiagramPower supply Electrical ConnectionsElectrical connection HeatMaster 150 Jumbo Commissioning Filling the HOT Water and Heating CircuitsACV BG 2000-S Premix GAS Burners Burner FeaturesACV BG 2000-S premix gas burners dimensions DescriptionL1 N T1 T2 S3 B4 Electrical connectionsACV premix gas burner BG 2000-S/60 and BG 2000-S/70 HM 60 N HM 70 N HM 100 N HM 150 Jumbo HeatMaster 60, 70 and 100 Gas burner features BGGas category M3/hBM oil burners dimensions FeaturesOil burner specification and perfomances ACV BM 101 and BM 151 OIL BurnersMaintenance Service IntervalsServicing the Boiler Draining the Boiler Servicing the Safety DevicesServicing the Burner Spare PartsUsing the Boiler User GuideUnderstanding the control panel Safety Valves Heating system pressureResetting the Pressure JET OIL or GAS Burner Resetting the BG 2000-S Premix GAS BurnerBurner Troubleshooting Service Record Date serviced Flue gas T Remarks Service Record Service Record World.com

150 JUMBO, 100 N, HM 60 N, 70 N specifications

The Heatmaster series, including the Heatmaster 150 JUMBO, 70 N, HM 60 N, and 100 N, represents a breakthrough in heating technology, designed to meet diverse heating needs with efficiency and reliability. Each model in this series offers unique features tailored for various applications, making the Heatmaster brand a prominent choice in the heating sector.

The Heatmaster 150 JUMBO stands out with its high-capacity output, capable of heating larger spaces effectively. It is equipped with an advanced burner technology that ensures optimal combustion efficiency, reducing fuel consumption and emissions. The model includes a user-friendly control panel with digital displays for temperature settings and operational statuses, allowing users to maintain precise heating levels effortlessly.

The Heatmaster 70 N is engineered for medium-sized areas, offering a perfect balance of power and portability. This unit is designed with an integrated heat exchanger that maximizes heat transfer while minimizing energy losses. Additionally, it features a robust safety system, including automatic shut-off mechanisms and thermal protection, ensuring both user safety and device longevity.

The HM 60 N model focuses on compact design without compromising performance. Its lightweight structure facilitates easy transport and installation, making it ideal for temporary heating solutions such as construction sites and event spaces. The HM 60 N utilizes a dual-fuel capability, allowing it to operate on either gas or electricity, thus providing flexibility based on the availability of resources.

Meanwhile, the Heatmaster 100 N model brings together enhanced durability and high efficiency, catering to various commercial and industrial applications. This model features an advanced insulation system that minimizes heat loss, ensuring a consistent output over extended periods. Additionally, the Heatmaster 100 N is built with high-quality materials that withstand tough environmental conditions, making it a reliable choice for challenging settings.

All models in the Heatmaster series come equipped with smart technologies that enable remote control and monitoring capabilities, allowing users to adjust settings from their smartphones or other devices. This feature not only enhances convenience but also promotes energy savings by optimizing usage patterns.

In summary, the Heatmaster 150 JUMBO, 70 N, HM 60 N, and 100 N are engineered to provide effective heating solutions for a myriad of environments. Their innovative technologies, safety features, and efficiency make them leaders in the heating market, well-suited for both residential and commercial applications. Investing in any of the Heatmaster models guarantees peace of mind and performance, making them a worthwhile addition to any heating strategy.