Heatmaster 70 N, HM 60 N, 150 JUMBO, 100 N manual Dimensions

Page 7

TECHNICAL SPECIFICATION

DIMENSIONS

The units are delivered fully assembled, tested and packed on a timber base with shockproof edges and protected by heat-shrunk plastic film. On reception and after unpacking, check the equipment for damage. For transport purposes, refer to the weight (page 5) and dimensions given below.

 

A mm

B mm

C mm

D mm

E mm

F mm

G Ø mm

H mm

J mm

K mm

 

 

 

 

 

 

 

 

 

 

 

HM 60 N

1698

1583

538

625

540

390

150

1098

281

1665

 

 

 

 

 

 

 

 

 

 

 

HM 60 N BG 2000-S 60

1698

1583

538

801

540

390

150

1098

281

1665

 

 

 

 

 

 

 

 

 

 

 

HM 70

1743

1630

678

797

680

390

150

1289

285

1720

 

 

 

 

 

 

 

 

 

 

 

HM 70 N BG 2000-S 70

1743

1630

680

937

680

390

150

1289

285

1720

 

 

 

 

 

 

 

 

 

 

 

HM 100 N

2093

2030

680

797

680

390

150

1693

285

2120

 

 

 

 

 

 

 

 

 

 

 

HM 100 N BG 2000-S 100

2093

2030

680

937

680

390

150

1693

285

2120

 

 

 

 

 

 

 

 

 

 

 

HM 150 Jumbo

2124

2117

1020

1440

1020

600

250

1383

590

2250

 

 

 

 

 

 

 

 

 

 

 

HeatMaster 60 N

Without burner

With ACV BG 2000-S

 

premix gas burner

 

 

 

 

 

 

A

F

G

A B

H K

C/2

J

C

 

C

D

D

E

6

Image 7
Contents HeatMaster Introduction IndexDescription Construction FeaturesOperating Principle Burner chamber plate Safety features of the HeatMaster 150 Jumbo Burner Chamber Plate Technical SpecificationGeneral Features Maximum Operating ConditionsDimensions 562 Boiler Room InstallationChimney Connections Balanced flue boiler connection type C C53HOT Water Connections OIL Supply Connections ACV BM Burners Heating ConnectionElectrical Connections Wiring DiagramPower supply SafetyElectrical connection HeatMaster 150 Jumbo Filling the HOT Water and Heating Circuits CommissioningDescription Burner FeaturesACV BG 2000-S premix gas burners dimensions ACV BG 2000-S Premix GAS BurnersElectrical connections L1 N T1 T2 S3 B4ACV premix gas burner BG 2000-S/60 and BG 2000-S/70 M3/h HeatMaster 60, 70 and 100 Gas burner features BGGas category HM 60 N HM 70 N HM 100 N HM 150 JumboACV BM 101 and BM 151 OIL Burners FeaturesOil burner specification and perfomances BM oil burners dimensionsService Intervals MaintenanceServicing the Boiler Spare Parts Servicing the Safety DevicesServicing the Burner Draining the BoilerUser Guide Using the BoilerUnderstanding the control panel Heating system pressure Safety ValvesResetting the BG 2000-S Premix GAS Burner Resetting the Pressure JET OIL or GAS BurnerBurner Troubleshooting Service Record Date serviced Flue gas T Remarks Service Record Service Record World.com

150 JUMBO, 100 N, HM 60 N, 70 N specifications

The Heatmaster series, including the Heatmaster 150 JUMBO, 70 N, HM 60 N, and 100 N, represents a breakthrough in heating technology, designed to meet diverse heating needs with efficiency and reliability. Each model in this series offers unique features tailored for various applications, making the Heatmaster brand a prominent choice in the heating sector.

The Heatmaster 150 JUMBO stands out with its high-capacity output, capable of heating larger spaces effectively. It is equipped with an advanced burner technology that ensures optimal combustion efficiency, reducing fuel consumption and emissions. The model includes a user-friendly control panel with digital displays for temperature settings and operational statuses, allowing users to maintain precise heating levels effortlessly.

The Heatmaster 70 N is engineered for medium-sized areas, offering a perfect balance of power and portability. This unit is designed with an integrated heat exchanger that maximizes heat transfer while minimizing energy losses. Additionally, it features a robust safety system, including automatic shut-off mechanisms and thermal protection, ensuring both user safety and device longevity.

The HM 60 N model focuses on compact design without compromising performance. Its lightweight structure facilitates easy transport and installation, making it ideal for temporary heating solutions such as construction sites and event spaces. The HM 60 N utilizes a dual-fuel capability, allowing it to operate on either gas or electricity, thus providing flexibility based on the availability of resources.

Meanwhile, the Heatmaster 100 N model brings together enhanced durability and high efficiency, catering to various commercial and industrial applications. This model features an advanced insulation system that minimizes heat loss, ensuring a consistent output over extended periods. Additionally, the Heatmaster 100 N is built with high-quality materials that withstand tough environmental conditions, making it a reliable choice for challenging settings.

All models in the Heatmaster series come equipped with smart technologies that enable remote control and monitoring capabilities, allowing users to adjust settings from their smartphones or other devices. This feature not only enhances convenience but also promotes energy savings by optimizing usage patterns.

In summary, the Heatmaster 150 JUMBO, 70 N, HM 60 N, and 100 N are engineered to provide effective heating solutions for a myriad of environments. Their innovative technologies, safety features, and efficiency make them leaders in the heating market, well-suited for both residential and commercial applications. Investing in any of the Heatmaster models guarantees peace of mind and performance, making them a worthwhile addition to any heating strategy.