Redring AE125, AE115 Using an Ohmmeter to check for Premature element failure, Water flow too low

Page 14

Using an Ohmmeter to check for Premature element failure

LEFT MODULE Top View

RIGHT MODULE Top View

Meter probes

Ohm Reading

 

Meter probes

Ohm Reading

Outer to Outer

10.5

± 0.5

Ohms

 

Outer to Outer

10.5

± 0.5

Ohms

Middle to Middle

11.5

± 0.5

Ohms

 

Middle to Middle

11.5

± 0.5

Ohms

Inner to Inner

15.0

± 1 Ohms

 

Inner to Inner

21.0

± 1 Ohms

Note: On AE115 model, there is no middle element.

 

 

Water flow too low

There are

Obstructions in the water path can restrict the flow of water through the heater.

restrictions in the

Verify the heater’s inlet filter screen, faucet aerators, showerheads and whole

plumbing

house filters are clear of debris. Verify proper flow on the outlet side of the heater

 

with the hot water pipe disconnected. Maximum flow rates for each unit are as

 

follows. AE115 = 2.3gpm, AE125 = 3.5gpm.

 

 

Water supply

Verify incoming water supply is at least 30psi. For people on well systems, the

pressure too low

recommended pressure range is 30-50psi.

 

 

Outlet shut-off

Adjust installer supplied outlet valve as described below:

valves are set too

Completely open both installer supplied inlet and outlet shut-off valves at the

low

heater. (if none installed, install before proceeding)

 

Completely open hot water on the highest flowing hot water fixture served by

 

the heater (i.e. bathtub).

 

Slowly close the outlet shut-off valve, slowing the water flow rate until the

 

 

temperature at the hot water faucet corresponds to the values given on

 

 

Graph 1 on Page 8 of the manual, or desired water temperature is reached.

 

 

 

14

Image 14
Contents Page Important Safety Instructions ContentsLocating the Powerstar Installing the PowerStarSpecifications AE115 Unit AE125 UnitWater Connections Mounting the PowerstarDiagram US wiring Electrical connectionsDiagram Connecting the supply cable Canada only not for the USA Not ForAdjusting the flow Starting up the PowerStarAdjusting the temperature dial Checking for leaks and purging airHow the PowerStar works For exampleUsing the PowerStar Spare Parts MaintenancePart Description Number Refer to Diagram 1, Check inlet water filter screen once a yearTroubleshooting Cold water only Neon light offWater too cold Neon light on Using an Ohmmeter to check for Premature element failure Water flow too lowWater Temperature Fluctuates PowerStarWater Temperature Too Hot Exclusions Bosch Water Heating Mad River Park Waitsfield VT Toll Free