ResMed S8 ESCAPE SYSTEM, s8 user manual Medical Information

Page 8

If oxygen is used with this device, the oxygen flow must be turned off when the device is not operating.

If oxygen has been left on, turn off the flow generator, then wait 30 minutes before turning on the flow generatory again.

Explanation: When the CPAP device is not in operation and the oxygen flow is left on, oxygen delivered into the air delivery tubing may accumulate within the CPAP machine enclosure and create a risk of fire. This applies to most types of CPAP machines.

Oxygen supports combustion. Oxygen should not be used while you are smoking or in the presence of an open flame.

Always ensure airflow is being generated by the device before the oxygen supply is turned on.

Always turn the oxygen supply off before stopping the airflow from the device.

Note: At a fixed rate of supplemental oxygen flow, the inhaled oxygen concentration will vary, depending on where the oxygen is introduced, the pressure settings, patient breathing pattern, mask selection, and leak rate.

Do not use the S8 ESCAPE if there are obvious external defects or unexplained changes in performance.

Do not open the S8 ESCAPE case. There are no user serviceable parts inside. Repairs and internal servicing should only be performed by an authorized service agent.

Explosion hazard—do not use in the vicinity of flammable anesthetics.

CAUTIONS

At low pressures, the flow through the exhalation ports of your mask may not clear all exhaled gas from the tubing. Some rebreathing may occur.

The airflow for breathing produced by this device can be as much as 11oF (6oC)

higher than the temperature of the room. Caution should be exercised if the room temperature is warmer than 90oF (32oC).

When AC mains power (100–240V AC) is not available, always use a ResMed DC-12 converter. (The DC-12 converter is available as an optional accessory. It is not supplied with all models.)

If supplied, the Data Card module is designed for use with specific ResMed devices.

Only use the Data Card module (if supplied) as specified in this manual.

Note: The above are general warnings and cautions. Specific warnings, cautions, and notes appear with the relevant instructions in the manual.

ENGLISH

MEDICAL INFORMATION

7

Image 8
Contents S8 Escape System S8 Escape 1234 Contents System Specifications Introduction Medical InformationContraindications Medical Information Adverse Effects S8 Escape System Shows the keypad and LCD screen, and the air outletHumidifiers HOW to USE the S8 Escape Stop Treatment HOW to Attach a Humidifier Attach a Resmed Passover Humidifier HOW to USE the Keypad LCD ScreenHOW to Change the Settings on Your S8 Escape Press the Right key Exit May appear when Press the Left Ok key to remove S8 Modules Insert the Data Card English Cleaning and Maintenance Replacing the AIR Filter Frequently Asked Questions International useAltitude changes Troubleshooting Problem Possible Cause SolutionMotor Fault Settings Error Remove Card System Specifications Power outlet for HumidAireElectromagnetic Compatibility RF emissions CISPR11 Group Page Recommended separation distance Separation distance according to frequency of transmitter Limited Warranty Page Index Weekly cleaning
Related manuals
Manual 158 pages 44.94 Kb Manual 50 pages 57.93 Kb Manual 88 pages 45.08 Kb Manual 47 pages 54.64 Kb Manual 20 pages 25.84 Kb

S8 ESCAPE SYSTEM, s8 specifications

The ResMed S8 Escape is a highly regarded CPAP (Continuous Positive Airway Pressure) device designed for the treatment of obstructive sleep apnea. Known for its reliability and user-friendly features, the S8 Escape is part of ResMed’s S8 series, which combines advanced technologies with an emphasis on patient comfort.

One of the standout features of the S8 Escape is its AutoRamp technology, which helps patients gradually transition into their prescribed pressure settings. Instead of starting at the full pressure immediately, AutoRamp begins at a lower pressure, allowing users to fall asleep comfortably before automatically increasing to the prescribed level. This feature significantly improves the overall user experience as it reduces anxiety associated with the use of CPAP devices.

The S8 Escape also boasts a built-in air filter that enhances air quality and protects the device from dust and other particulates. Additionally, the device is designed for whisper-quiet operation, ensuring that users can sleep soundly without the disruption of noise, which can be a common issue with less advanced models. This creates a more peaceful sleeping environment, both for the user and their bed partner.

Another important characteristic of the S8 Escape is its compact design and lightweight build. It is easily portable, making it an ideal choice for both home use and travel. The device also features a user-friendly interface, with a simple LCD screen that displays essential information such as pressure settings and therapy time. This allows users to track their usage and monitor their therapy progress conveniently.

The S8 Escape offers various pressure settings and is compatible with a wide range of masks, ensuring that users can find the right fit for their individual needs. The device’s advanced monitoring capabilities also help in providing feedback on therapy effectiveness, allowing healthcare professionals to adjust settings if necessary.

In summary, the ResMed S8 Escape is a highly functional and patient-friendly CPAP device, featuring advanced technologies designed to enhance the user experience. Its AutoRamp technology, quiet operation, and compact design make it a popular choice among individuals dealing with obstructive sleep apnea.