Reliance Water Heaters 317686-000 instruction manual Troubleshooting Guidelines, Trouble Shooting

Page 35

TROUBLESHOOTING GUIDELINES

TROUBLE SHOOTING

Please check guidelines below. For your safety, water heater service should be performed only by a qualified service technician.

Read the GENERAL SAFETY INFORMATION section first.

INTELLI-VENT TROUBLESHOOTING CHART - USER CONTROL

#

1

2

3

4

5

6

LED STATUS

PROBLEM

 

SOLUTION

 

 

 

1

Ensure the wall outlet (power supply) is properly

 

 

The gas control valve/thermostat

 

grounded.

 

 

 

 

 

has sensed inadequate or no earth

 

 

 

 

ground.

2

Ensure all ground connections/wires on the water

 

 

 

 

 

 

heater are securely connected.

 

 

The gas control valve/thermostat

1

Ensure the wall outlet/power supply is properly wired.

 

 

 

 

 

 

 

 

 

 

has sensed reversed polarity in the

2

Ensure all internal 120 VAC wiring connections and

 

 

120 VAC power supply.

 

wiring harness have no reversed wires. 120 VAC "hot"

 

 

 

 

 

 

 

wire must connect to the on/off switch.

 

 

Pressure switch circuit remaining

 

 

 

 

closed for more than 5 seconds

1

Ensure air pressure switch circuit wiring is correct and

 

 

after heating cycle begins.

 

the air pressure switch is not jumpered.

 

 

Blower may not start in this

2

Replace the air pressure switch.

 

 

 

 

condition.

 

 

 

 

 

1

Ensure the air pressure switch sensing tube is properly

 

 

 

 

connected at both ends and is not kinked or damaged.

 

 

Pressure switch circuit remains

2

Ensure the correct size of vent and intake air pipe (direct

 

 

 

vent products) was used per the installation instructions

 

 

open longer than 5 seconds after

 

 

 

 

in the manual that came with the water heater.

 

 

the blower is energized.

 

 

 

 

 

 

 

Blower may run continuously in

3

Ensure maximum number of elbows or maximum

 

 

 

 

 

equivalent feet of vent or intake air pipe has not been

 

 

this condition.

 

 

 

 

exceeded per the installation instructions in the manual

 

 

 

 

 

 

 

 

that came with the water heater.

 

 

 

4

Ensure there are no obstructions in the vent or intake air pipe.

 

 

 

1

Check wiring to the hot surface igniter assembly -

 

 

 

 

replace igniter assembly if wiring is damaged or worn.

 

 

 

2

Check resistance of the igniter at igniter assembly

 

 

 

 

plug - should be between 11 and 18 ohms at room

 

 

 

 

temperature (77° F at plug end) - replace igniter if open

 

 

The gas control valve/thermostat

 

or shorted.

 

 

3

Check igniter assembly plug and the socket on the gas

 

 

has detected an open igniter circuit.

 

 

 

 

control valve/thermostat for good connection.

 

 

 

4

Replace igniter assembly if the plug is worn or damaged.

 

 

 

5

Replace the gas control valve/thermostat if the igniter

 

 

 

 

assembly socket on the bottom of the control is worn or

 

 

 

 

damaged.

 

 

 

1

Ensure flame sensor is making good contact with the

 

 

 

 

burner flame and ensure flame is steady. Also ensure

 

 

Ignition/flame failure.

 

supply and manifold gas pressures are within the

 

 

 

requirements in the installation manual.

 

 

The gas control valve/thermostat

2

Gas supply is turned off - pressure is too low.

 

 

 

 

 

 

has reached the maximum number

3

Ensure the flame sensor is clean - use fine steel wool

 

 

 

 

of retries (3) for ignition and is

 

to clean the flame sensor.

 

 

currently locked out for one hour.

4

Check igniter assembly plug and the socket on the

 

 

 

 

 

 

 

Cycle the power to the water heater

 

bottom of the gas control valve/thermostat for good

 

 

 

connection. Replace igniter assembly if the plug is worn

 

 

off and on to reset.

 

or damaged. Replace the gas control valve/thermostat if

 

 

 

 

socket is worn or damaged.

 

 

 

5

Replace igniter assembly.

 

 

 

 

 

35

Image 35
Contents 317686-000 Whenever maintenance adjustment or service is requiredPrinted Important Definitions Safe INSTALLATION, USE and ServiceApprovals General Safety Information General Safety Information Introduction Table of ContentsExemptions Installation of Carbon Monoxide DetectorsApproved Carbon Monoxide Detectors SignageElbow Access Door Typical InstallationReplacement Parts and Deliming Products Condensate Hose and Drain PAN Less Severe Burns 2nd & 3rd Degree Mixing ValvesFacts to Consider About the Location Locating the NEW Water HeaterAir REQUIREMENTs Insulation BlanketsOutdoor Air Through Two Openings Unconfined SpaceConfined Space Fresh Air Openings For Confined SpacesAIR from Other Indoor Spaces Outdoor AIR Through TWO Horizontal DuctsOutdoor AIR Through TWO Vertical Ducts Space Heating and Potable Water System Installing the NEW Water HeaterChemical Vapor Corrosion Water PipingValve and Pipe Insulation Temperature-Pressure Relief ValveThermal Expansion Gas Piping High Altitude InstallationFilling the Water Heater Sediment TrapsVenting Vent Pipe AssemblyVent Pipe Termination Termination Clearances Sidewall Power VentBreathing Hazard Carbon Monoxide Gas Planning the Vent SystemCondensate Vent Terminal INSTALLATION, Sidewall Blower Assembly InstallationInstallation of Vent System Vent Termination Figure Sequence of INSTALLATIONS, FigurePower Vent Wiring Schematic Figure Installation of Vertical Vent System Installation of Vent SYSTEM, SidewallVertical VAA Installations Recommended Vent Attenuation Assembly InstallationInch vent Vertical VAA Installations Recommended BRUSH* Size for Primer Cement Applications Vent Pipe PreparationStep G Step BStep E Step FPage GAS Control Valve Front View Temperature RegulationOperational Conditions Periodic MaintenanceFor Your Information Start UP ConditionsAnode ROD Inspection Burner CleaningBurner Operation and Inspection HousekeepingTo Flush the Water Heater Storage Tank Temperature-Pressure Relief Valve TestDraining and Flushing To Drain the Water Heater Storage TankLeakage Checkpoints ServiceRepair Parts List LED Status Problem Solution Troubleshooting GuidelinesTrouble Shooting LED Status Problem Solution Troubleshooting Guidelines Troubleshootinotesg Guidelines Limitation on Implied Warranties Service and Labor ResponsibilityClaim Procedure Conditions and Exceptions

317686-000, 6 50YTVIT SERIES 100 specifications

The Reliance Water Heaters 6 50YTVIT Series is a top-performing line of electric water heaters designed to deliver reliable hot water for residential needs. This model, identified by the part number 100,317686-000, showcases exceptional efficiency and innovative features that make it a popular choice among homeowners.

One of the standout characteristics of the 6 50YTVIT is its 50-gallon capacity, providing ample hot water to meet the demands of larger households. The tank is constructed from durable materials to ensure longevity, featuring a glass-lined interior that helps resist corrosion, extending the lifespan of the unit.

An important feature of this water heater is its energy efficiency. It is built with a high-efficiency heating element that reduces energy consumption, ultimately leading to lower utility bills. The unit also has an ENERGY STARĀ® certification, indicating it meets strict energy efficiency guidelines set by the Environmental Protection Agency. This makes it not only an eco-friendly choice but also a cost-effective one.

The Reliance 6 50YTVIT is equipped with advanced safety mechanisms, including a combination temperature and pressure relief valve, which protects the unit from overheating or excessive pressure build-up. This ensures safe operation, providing peace of mind for users.

Installation and maintenance are made easier with the thoughtful design of this water heater. Its lightweight construction facilitates hassle-free handling and installation, even in tighter spaces. Additionally, the unit is designed for easy access to the heating elements for maintenance, helping to reduce downtime and cost.

Technologically, this water heater adopts a versatile voltage system, making it compatible with a wide range of electrical supplies. It can operate effectively in various home settings, enhancing its adaptability.

In conclusion, the Reliance Water Heaters 6 50YTVIT Series 100,317686-000 stands out for its robust capacity, energy efficiency, and safety features. Its dependable performance and ease of maintenance make it an ideal choice for homeowners looking for a reliable water heating solution that ensures comfort and convenience in daily life. With its thoughtful design and competitive features, the Reliance 6 50YTVIT series continues to be a preferred selection in modern home water heating applications.