VACUUM RELIEF
VALVE
*INSTALL PER
LOCAL CODES
* CAUTION HARNESS HAS 120 VAC. IN OPERATION.
** See “PLANNING THE VENT SYSTEM”, “CONDENSATE” and “BLOWER ASSEMBLY INSTALLATION” for more information.
***The side recirculation loop connections may not be used as the primary water inlet and outlet connections. For your convenience, plugs are installed in these fittings at the factory. Remove these plugs if needed for your specific installation. Otherwise (as with all connections) check for leaks while filling the tank with water and after completing the installation.
FIGURE 1 7

TYPICAL INSTALLATION

GET TO KNOW YOUR WATER HEATER - GAS MODELS

AVent Pipe

BAnode

CHot Water Outlet

D Outlet (120 VAC)

FGas Supply

GMain Manual Gas Shut Off Valve

HGround Joint Union J Dirt Leg

KOuter Door

LUnion

MInlet Water Shut Off Valve

NCold Water Inlet

OInlet Dip Tube

PTemperature & Pressure Relief Valve

Q

Rating Plate

H H

Bushing

R

Insulation

II

Nipple

S

Vent Terminal

JJ

Condensate Tee

T

Drain Valve

KK

Adapter

U

Igniter And Main Burner

LL

Plug

W

Drain Pan

MM

Vent Pipe Assembly #1

X

Control

NN

Vent Pipe Assembly #2

Y

Control Harness*

OO

Vent Pipe Assembly #3

AA

Motor & Blower

PP

Side Recirculation Loop

CC

Condensate Fitting

QQ

Inlet***

DD

(4 Places Shown)**

Side Recirculation Loop

Plastic Top

RR

Outlet*** (not shown)

EE

On/Off Switch

Vent Attenuation

FF

Exhaust Tee

SS

Assembly (VAA) (Optional)

GG

Elbow

Access Door

REPLACEMENT PARTS AND DELIMING

PRODUCTS

Replacement parts and recommended delimer may be ordered through authorized servicers or distributors. When ordering parts, provide complete model and serial numbers (see rating plate), quantity and name of part desired. Standard hardware items may be purchased locally.

SS

(SEE ACCESS

PANEL CAUTION)

W

PP

6(15cm)

MAXIMUM AIR GAP

TO A SUITABLE

DRAIN

CONDENSATE ASSEMBLY

(U)NATURAL GAS MAIN BURNER

WITH IGNITER ASSEMBLY

SIDE VIEW

(X)TEMPERATURE INDICATORS

TEMPERATURE ADJUSTMENT BUTTONS

Image 7
Contents 317775-000 Power Vented GAS Models W/HOT Surface IgnitionWhenever maintenance adjustment or service is required PrintedApprovals Safe INSTALLATION, USE and ServiceImportant Definitions General Safety Information General Safety Information Introduction Table of ContentsExemptions Installation of Carbon Monoxide DetectorsApproved Carbon Monoxide Detectors SignageReplacement Parts and Deliming Products Typical InstallationElbow Access Door Condensate Hose and Drain PAN Mixing Valves Recovery capacity based on 90% thermal efficiency ROUGH-IN-DIMENSIONSRough-In-Dimensions Capacity and Gas and Electrical CharacteristicsFacts to Consider About the Location Locating the NEW Water HeaterAir REQUIREMENTs Insulation BlanketsOutdoor Air Through Two Openings Unconfined SpaceConfined Space Fresh Air Openings For Confined SpacesOutdoor AIR Through TWO Vertical Ducts Outdoor AIR Through TWO Horizontal DuctsAIR from Other Indoor Spaces Space Heating and Potable Water System Installing the NEW Water HeaterChemical Vapor Corrosion Water PipingThermal Expansion Temperature-Pressure Relief ValveValve and Pipe Insulation if supplied Contact qualified installer or service agency High Altitude InstallationGas Piping Filling the Water Heater Sediment TrapsPer square inch 3.5 kPa Venting Vent Pipe AssemblyVent Pipe Termination Termination Clearances Sidewall Power VentCondensate Planning the Vent SystemBreathing Hazard Carbon Monoxide Gas Installation of Vent System Blower Assembly InstallationVent Terminal INSTALLATION, Sidewall Pointed in the correct position, see Figure Power Vent Wiring Schematic FigureChisel an opening approximately one half inch 1.3 cm larger Than the marked circleInstallation of Vertical Vent System Installation of Vent SYSTEM, SidewallVent attenuation assembly Flexible tubing Instruction sheet Vent Attenuation Assembly InstallationVertical VAA Installations Recommended Inch vent Vertical VAA Installations Recommended BRUSH* Size for Primer Cement Applications Vent Pipe PreparationStep G Step BStep E Step FDo not TRY to Light the Burner by Hand Power Before ServicingDo not try to light the burner by hand What to do if YOU Smell GASD E F Temperature RegulationTemperature Indicators Temperature Adjustment Buttons DisplayStart UP Conditions For Your InformationOperational Conditions Anode ROD Inspection Periodic MaintenanceOpen the water heater drain valve to flush the storage tank Temperature-Pressure Relief Valve TestKeep hands clear of drain To Flush the Water Heater Storage TankLeakage Checkpoints ServiceTrouble Shooting Troubleshooting GuidelinesUnplug ignitor assembly plug from control. Check resistance Ensure the flame sensor is clean use ultra fine steelTurn off power to the water heater Assembly if damaged or defectiveCheck vent temperature limit switch if it is determined Unplug the ignitor assembly plug from the control. CheckResistance of the black resistor wire between pins Assembly .2 If the reading taken is less than 100,000Troubleshooting Guidelines Limited Warranty

317775-000, HE50 76N Series 100 specifications

The Reliance Water Heaters HE50 76N Series 100,317775-000 is a remarkable product tailored to meet the increasingly demanding needs of modern households. Known for its reliability and efficiency, this water heater stands out in both functionality and design, making it a preferred choice for many homeowners.

One of the primary features of the HE50 76N series is its impressive 50-gallon capacity, which provides ample hot water for various domestic tasks such as bathing, cooking, and cleaning. This generous size makes it suitable for medium to large families, ensuring that you can enjoy hot water when you need it most without any disruptions.

The heater is equipped with an Energy Factor (EF) rating that reflects its efficiency in converting energy into hot water. Designed for optimal energy savings, the HE50 76N series features advanced insulation that minimizes heat loss, thus reducing energy bills and promoting sustainability. The insulation also contributes to maintaining a consistent water temperature, ensuring comfort and convenience.

One of the standout technologies integrated into this model is the use of a powerful heating element, which rapidly heats the water. This system ensures quick recovery times, allowing for uninterrupted hot water supply even during peak usage. Additionally, the HE50 76N is equipped with a thermostat that enables users to easily adjust the temperature settings according to their preference, enhancing user control and safety.

Reliance has also prioritized durability and longevity in the design of the HE50 76N series. With a corrosion-resistant tank and protective coatings, this water heater is built to withstand the rigors of daily use and resist the elements that typically contribute to wear and tear. The anode rod included in the tank provides extra protection against rust and helps prolong the lifespan of the heater.

Another significant characteristic of the HE50 76N series is its user-friendly interface. With straightforward controls and clear indicators, it makes operation simple for all users. Furthermore, installation is hassle-free, with standard connections that allow for easy integration into existing setups.

In summary, the Reliance Water Heaters HE50 76N Series 100,317775-000 combines efficiency, capacity, technology, and user-friendliness, making it one of the most reliable options on the market. With its emphasis on energy savings and durability, this water heater is designed to support the modern household while providing peace of mind and comfort.