mAINTENANCE

venting system

Examine the venting system every six months for obstructions and/or deterioration of the vent piping.

Remove all soot or other obstructions from chimney which will retard free draft.

remote storage tank temperature control

The water temperature in the remote storage tank (if used) is controlled by the storage tank temperature control. The sensing element is mounted in the hot water storage tank, see Water Piping Diagram section.

A change in water temperature in the storage tank lower than the tank temperature control setting will cause the sensor to activate the circulating pump. The pump then circulates the water through the heater where the thermostat senses the drop in water temperature and activates main burner operation of the appliance.

If the storage tank temperature control is out of calibration, replace with new control.

SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO SHUT OFF, TURN OFF THE MANUAL GAS CONTROL VALVE TO THE APPLIANCE.

temperature-Pressure relief Valve test

Burn hazard.

Hot water discharge.

Keep clear of Temperature- Pressure Relief Valve discharge outlet.

It is recommended that the Temperature-Pressure Relief Valve should be checked to ensure that it is in operating condition every 6 months.

When checking the Temperature-Pressure Relief Valve operation, make sure that (1) no one is in front of or around the outlet of the Temperature-Pressure Relief Valve discharge line, and (2) that the water discharge will not cause any property damage, as the water may be extremely hot. Use care when operating valve as the valve may be hot.

To check the relief valve, lift the lever at the end of the valve several times, see Figure 26. The valve should seat properly and operate freely.

If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater and drain the water heater, see Draining And Flushing on page 28. Replace the Temperature-Pressure Relief

Valve with a properly rated/sized new one, see Temperature- Pressure Relief Valve on pages 12-13 for instructions on replacement.

FIGURE 26.

If the Temperature-Pressure Relief Valve on the water heater weeps or discharges periodically, this may be due to thermal expansion.

NOTE: Excessive water pressure is the most common cause of Temperature-Pressure Relief Valve leakage. Excessive water system pressure is most often caused by "thermal expansion" in a "closed system." See Closed Water Systems and Thermal Expansion on page 12. The Temperature-Pressure Relief Valve is not intended for the constant relief of thermal expansion.

Temperature-Pressure Relief Valve leakage due to pressure build up in a closed system that does not have a thermal expansion tank installed is not covered under the limited warranty. Thermal expansion tanks must be installed on all closed water systems.

DO NOT PLUG THE TEMPERATURE-PRESSURE RELIEF VALVE OPENING. THIS CAN CAUSE PROPERTY DAMAGE, SERIOUS INJURY OR DEATH.

Explosion Hazard

Temperature-Pressure Relief Valve must comply with ANSI Z21.22- CSA 4.4 and ASME code.

Properly sized temperature- pressure relief valve must be installed in opening provided.

Can result in overheating and excessive tank pressure.

Can cause serious injury or death.

hot water odor

On occasion, hot water may develop a strong odor. If this occurs drain the heater completely, flush thoroughly, and refill. If the problem persists, chlorination of the heater and replacement of magnesium anodes with aluminum anodes may correct the condition.

Occasionally water softener companies recommend removal of heater anodes for odor reasons.

Unauthorized removal of the anode(s) will void the warranty. For further information contact your dealer.

28

Image 28
Contents Installation Operation Service Commercial gas water heatersTable Of Contents Safe Installation, Use and Service ApprovalsGeneral Safety Information Fire and Explosion HazardGrounding Instructions PrecautionsHydrogen Gas Flammable Qualified Installer or Service Agency IntroductionAbbreviations Used QualificationsHydro Cannon self-cleaning system High limit switchLow Gas Pressure Switch Electronic ignition controlInstallation considerations Rough In DimensionsROUGH-IN-DIMENSIONS Recovery CAPACITIES, based on 80% efficiencyLocating the water heater ClearancesInstallation on combustible flooring Insulation BlanketHard Water Circulation pumpsHigh Altitude Installations Installation Requirements Power SupplyWater Temperature Control and Mixing Valves Gas pressure requirementsTemperature-pressure relief valve Dishwashing MachinesClosed Water Systems Thermal ExpansionAir requirements Contaminated AirValve Discharge Pipe Requirements Confined Space Unconfined SpaceVenting Multiple heater manifold Fresh Air Openings For Confined SpacesOutdoor Air Through Two Openings Outdoor Air Through One OpeningOutdoor Air Through Two Vertical Ducts Air From Other Indoor SpacesType B GAS Vent Multiple Gas Fired Tank-Type HeatersTechnical Data Venting Water Line Connections Water heater installationValve Discharge Pipe Tube Inlet Installation Heater wiring GAS Piping GAS Supply Pipe Lengths in FeetPurging GAS Pressure RegulatorGeneral AdjustmentsFilling Lighting & Operation Label Check the Igniter Assembly Igniter AssemblyChecking Venting Main BurnerChecking the Input MAINTENANCE Remote storage tank temperature controlTemperature-Pressure relief Valve test Venting systemAnode rod inspection Draining and flushingTo Drain the Water Heater Storage Tank To Flush the Water Heater Storage TankDeliming Using FLO-JUG Method Tank Cleanout ProcedureDeliming solvents System diagnostics Ignition module systemHigh Water Temperature Shut OFF System For Your InformationElectrical Servicing Start up conditionsSequence of Operation Flow Chart Operational checklist Complaint Cause Remedy User Service AgentDiagrams Water PipingTemperature & Pressure Temperature & Pressure Relief Valve Circulating Pump Multi Flue 2 Units Multi Flue 2 Units with Vertical Storage Tank Multi Flue 2 Units with Vertical Storage Tank Return from Multi Flue 2 Units TWO Temperature Multi Flue 2 Units with Booster TWO Temperature MULTI-FLUE 3 Units MULTI-FLUE 3 Units with Vertical Storage Tank MULTI-FLUE 3 Units with Horizontal Storage Tank Multi Flue Flue 4 Units MULTI-FLUE 4 Units with Vertical Storage Tank MULTI-FLUE 4 Units with Horizontal Storage Tank Manifold Kits Page Page Page Page Limited Warranty Tennessee Waltz Parkway, Ashland City, TN Tech Support Parts

N71120NE, N85390NE specifications

Reliance Water Heaters has established itself as a trusted name in the water heating industry, consistently delivering high-quality products that meet the diverse needs of consumers. Among their offerings, the Reliance N71120NE and N85390NE models stand out due to their advanced features and innovative technologies.

The Reliance N71120NE is known for its efficient heating capabilities, boasting a 40-gallon capacity that is ideal for medium-sized households. This model features a durable glass-lined tank that provides exceptional resistance to rust and corrosion, ensuring longevity and durability. One of its standout characteristics is the built-in energy-saving mode, which optimizes energy consumption without compromising performance. This unit operates on electricity, making it a versatile option for various settings. Additionally, the N71120NE is designed with a temperature control thermostat, allowing users to set and maintain their desired water temperature with ease.

On the other hand, the Reliance N85390NE model offers a larger capacity of 50 gallons, making it suitable for larger families or homes with increased hot water demands. Similar to the N71120NE, this model comes with a glass-lined tank for superior protection against corrosion. One of the advanced technologies featured in the N85390NE is the High-Quality Insulation System, which minimizes heat loss and maintains water temperature efficiently. This model also includes a self-diagnostics system, providing users with real-time updates on performance and maintenance needs. The innovative anode rod in this unit extends the lifespan of the tank by sacrificially corroding instead of the tank itself.

Both models are designed with safety in mind, featuring a pressure relief valve that prevents pressure buildup, making them safe for residential use. Moreover, each unit adheres to the latest energy efficiency standards, contributing to reduced utility bills and a smaller carbon footprint.

Reliance Water Heaters emphasizes user-friendly installation and maintenance, making it easy for homeowners to enjoy the benefits of these advanced water heaters. Overall, the Reliance N71120NE and N85390NE models represent excellence in water heating technology, offering efficient, reliable, and user-friendly solutions for modern households. Choosing either of these models ensures that users can enjoy hot water on demand while benefiting from enhanced efficiency and durability.