QHT Boiler manual 3WOOD boiler piping and wiring Considerations

Page 24

3WOOD boiler piping and wiring Considerations

Before choosing a particular system for your installation, the possibility of using a mixing valve arrangement to avoid the problems of overheating should be considered. These systems will continuously release heat to the distribution system in proportion to the outside temperature or other load factor. Such an arrangement can be added to any heating system, and is one of the most sophisticated methods of heating system regulation available. We strongly recommend a mixing system with all of our solid fuel systems.

A.3WOOD AS THE ONLY BOILER

The 3WOOD boiler can be used as the only boiler in your heating system. Of course, the disadvantage of the installation is that there will be no automatic back-up system for times when the solid fuel fire will be unattended. For automatic switch-over from solid fuel to oil or gas, a tandem hookup of the 3WOOD with a second oil or gas boiler is recommended (see Section B). The obvious advantage of this set-up is the cost saving involved in the elimination of the conventional boiler, controls and piping required. It should be noted that the 3WOOD boiler is extremely efficient when fired with wood or coal. Many people use the 3WOOD boiler in conjunction with direct vent gas or electric space heaters located in the living spaces.

The following outlines a typical installation of a stand-alone 3WOOD boiler in a system planned for solid fuel firing.

1. The supply tapping goes to the heating radiation. Install a “tee” with a 1” branch in the line to the radiation, as close to the boiler as possible. This branch tee should point up and will route the piping to the “dump zone”. There must not be a valve or any potential restriction between the boiler and this tee.

2. in the boiler supply piping, install an air purger and expansion tank sized to handle the water in the distribution system as well as the 3WOOD boiler.

3. Pipe the make-up water into the boiler through a Watts 1156F fill valve (pressure reducing valve) into the lower rear ½” tapping at the bottom of the boiler.

4. Install a tee with a 1” branch for the dump zone in the return tapping. Point the branch of the tee up.

5. The circulator should be installed in the return line from the heating radiation. The return is piped into the boiler through the running end of the tee.

6. A circulator relay, Honeywell R845 or equivalent may control the circulator. Both the room thermostat and the Overheat Aquastat installed in the 3WOOD boiler control this relay.

NOTE: In a case where the thermostat is calling for heat and boiler fire is out or otherwise unable to meet the heating demands of the house, the circulator will continue to run. This has the advantage of helping prevent the water in the system from freezing if the house temperature drops below 32F. If the circulator is deactivated, the system must be drained if subfreezing interior temperatures are anticipated! As an alternative to draining the system, a mixture of heating system, anti-freeze (propylene glycol) and water can be used in place of normal water in the system. Such a mixture should only be added after the system is thoroughly checked for leaks.

24

Image 24
Contents 3Wood Cast Iron Boiler Page Table of Contents Important Information Page Identification Procedure in Event of Power Failure Refueling the Boiler Wood Burning Wood Storage Procedure in the event of a runaway fire or chimney fire Chimney Cleaning Chimney ConstructionCoal Fire 3WOOD Design Technology with 3 PassInstallation considerations Layout of the Main Components Recommended Minimum Clearances No Galvanized Pipe Assembling the Casing Installation of Controls Installation of Draft Regulator Installation of Flue Gas PartitionChain must be exactly 32 inches long Commissioning the 3WOOD Boiler Or the handle3WOOD boiler piping and wiring Considerations 3Wood installed in combination with a oil/gas boiler Piping NotesPage Way Mixing Valve Piping Page Boiler Parallel Piping Page Page 59200628,59200629 Page Page Shutdown Troubleshooting System Checkout Warranty for Biasi 3WOOD Residential Cast-Iron Water Boilers Biasi S.p.A Verona, Italy

Boiler specifications

The QHT Boiler is an advanced heating solution designed for both residential and commercial applications. Known for its efficiency and innovative technology, the QHT Boiler has rapidly gained recognition in the industry for its unique features and superior performance.

One of the main characteristics of the QHT Boiler is its high-efficiency rating. Utilizing cutting-edge technology, the boiler operates at a remarkably high thermal efficiency, which not only reduces energy consumption but also lowers operational costs for users. This efficiency is achieved through smart design and effective heat exchange systems that ensure maximum utilization of fuel.

Another notable feature of the QHT Boiler is its compact and space-saving design. Many models are engineered to be installed in tight spaces while still delivering powerful heating capabilities. This is especially valuable in urban environments where space is at a premium. The boiler’s sleek design also ensures that it can blend seamlessly with modern home aesthetics.

In terms of technology, the QHT Boiler incorporates advanced control systems that allow for precision temperature management. Users can easily set and adjust the desired temperatures through an intuitive interface, whether via a digital display or a mobile application. This flexibility ensures that heating needs are met efficiently, providing comfort without excess energy use.

Durability and reliability are key characteristics of the QHT Boiler. Constructed from high-quality materials, the boiler is designed to withstand the rigors of daily operation while minimizing the need for maintenance. This reliability is crucial for both homeowners and businesses, as it translates to reduced downtime and long-term cost savings.

Sustainability is another critical focus of the QHT Boiler’s design. Many models are compatible with renewable energy sources, including solar thermal systems, allowing users to reduce their carbon footprint. The incorporation of features like modulating burners helps to adjust the combustion process to varying heat demands, resulting in lower emissions.

Safety features are also paramount in the QHT Boiler’s design. It includes multiple safety mechanisms such as pressure relief valves and flame detection sensors to ensure safe operation. These features provide peace of mind to users, knowing that the boiler operates within safe parameters.

In summary, the QHT Boiler represents a fusion of efficiency, advanced technology, and user-friendly design, making it a top choice for heating solutions. With its compact size, high-efficiency rating, innovative control systems, and commitment to sustainability, the QHT Boiler stands out as a modern solution for diverse heating needs. Whether for residential or commercial use, it meets the demands of today’s energy-conscious consumers.