QHT manual Refueling the Boiler

Page 8

REFUELING THE BOILER

CAUTION

Use extreme caution when refueling the boiler. If the door is opened too quickly, the unburned hot gases may ignite and cause a back puff. This is especially true with very dry wood.

DO NOT tamper with the chain on the draft regulator as it could cause the fire to burn out of control.

Keep ash and fuel doors closed if not refueling boiler.

DO NOT overload the boiler.

Adjusting the Flue Gas Damper

To Re-fire the boiler, open the flue gas damper to establish more draft through the combustion chamber. Af- ter refueling, when the fire is established, it probably will be necessary to close the flue gas damper to match the heating requirements and accommodate the chimney draft.

Reloading Wood

CAUTION

To reload wood in the firebox, Carefully open the top fire door an inch or so until you can see that the fire is burning well and the smoke is exhausting up into the heat exchanger above the firebox. While loading, the door can be left fully open and logs can be added by swinging the flue gas damper open. Logs should be 1” or 2” shorter than the firebox in the boiler and should be of such diameter as not to “bridge” or jam in the firebox. Logs of 2” to 4” in diameter should be used whenever possible. This will produce an even burning and efficient fire. Wood split to this size also dries much more quickly. The logs should be stacked and lined up horizontally so the burning wood can settle easily. Add the largest wood when the fire is burning well and some coals are forming. After you have filled the firebox to the desired level, close the loading door securely. Damage or injury will result if wood is not loaded carefully generally level with bottom of flue gas damper. If loaded in-correctly there is a risk of fire or injury.

In long- term maintenance of the boiler fire, frequent stoking with small amounts of wood is better than in- frequent stoking with larger amounts. When you stoke the fire, pull some of the hot coals forward in the firebox where they can get sufficient air to burn thereby enabling them to set fire to the next load of wood.

Draft Regulator

The draft regulator should be adjusted as follows:

It may take several trials adjusting the Samson control setting to maintain the proper boiler temperature during wood firing of approximately 180-190°F. The final control setting may be a little more or a little less then the red 80°C on the dial. During normal operation, especially in the spring or fall, it is necessary to allow air to enter through the secondary air damper. This method reduces the possibility of creosote formation when the lower air flap is fully closed.

1.Turn the black knob counterclockwise to set the red number from 40°C to 80°C at the red line.

2.Allow the wood fire to slowly bring the boiler temperature up to about 180°F on the temperature gauge.

3.As this temperature is reached, the lower door air inlet flap will begin to close because the proper combustion of air has entered the firebox to maintain the selected boiler temperature.

DO NOT tamper with the chain on the draft regulator as it could cause the fire to burn out of control.

CAUTION

Empty the ashes before they touch the grates so they will not interfere with the airflow to the vertical flue

passages

8

Image 8
Contents 3Wood Cast Iron Boiler Page Table of Contents Important Information Page Identification Procedure in Event of Power Failure Refueling the Boiler Wood Burning Wood Storage Procedure in the event of a runaway fire or chimney fire Chimney Cleaning Chimney ConstructionCoal Fire 3WOOD Design Technology with 3 PassInstallation considerations Layout of the Main Components Recommended Minimum Clearances No Galvanized Pipe Assembling the Casing Installation of Controls Installation of Draft Regulator Installation of Flue Gas PartitionChain must be exactly 32 inches long Commissioning the 3WOOD Boiler Or the handle3WOOD boiler piping and wiring Considerations 3Wood installed in combination with a oil/gas boiler Piping NotesPage Way Mixing Valve Piping Page Boiler Parallel Piping Page Page 59200628,59200629 Page Page Shutdown Troubleshooting System Checkout Warranty for Biasi 3WOOD Residential Cast-Iron Water Boilers Biasi S.p.A Verona, Italy

Boiler specifications

The QHT Boiler is an advanced heating solution designed for both residential and commercial applications. Known for its efficiency and innovative technology, the QHT Boiler has rapidly gained recognition in the industry for its unique features and superior performance.

One of the main characteristics of the QHT Boiler is its high-efficiency rating. Utilizing cutting-edge technology, the boiler operates at a remarkably high thermal efficiency, which not only reduces energy consumption but also lowers operational costs for users. This efficiency is achieved through smart design and effective heat exchange systems that ensure maximum utilization of fuel.

Another notable feature of the QHT Boiler is its compact and space-saving design. Many models are engineered to be installed in tight spaces while still delivering powerful heating capabilities. This is especially valuable in urban environments where space is at a premium. The boiler’s sleek design also ensures that it can blend seamlessly with modern home aesthetics.

In terms of technology, the QHT Boiler incorporates advanced control systems that allow for precision temperature management. Users can easily set and adjust the desired temperatures through an intuitive interface, whether via a digital display or a mobile application. This flexibility ensures that heating needs are met efficiently, providing comfort without excess energy use.

Durability and reliability are key characteristics of the QHT Boiler. Constructed from high-quality materials, the boiler is designed to withstand the rigors of daily operation while minimizing the need for maintenance. This reliability is crucial for both homeowners and businesses, as it translates to reduced downtime and long-term cost savings.

Sustainability is another critical focus of the QHT Boiler’s design. Many models are compatible with renewable energy sources, including solar thermal systems, allowing users to reduce their carbon footprint. The incorporation of features like modulating burners helps to adjust the combustion process to varying heat demands, resulting in lower emissions.

Safety features are also paramount in the QHT Boiler’s design. It includes multiple safety mechanisms such as pressure relief valves and flame detection sensors to ensure safe operation. These features provide peace of mind to users, knowing that the boiler operates within safe parameters.

In summary, the QHT Boiler represents a fusion of efficiency, advanced technology, and user-friendly design, making it a top choice for heating solutions. With its compact size, high-efficiency rating, innovative control systems, and commitment to sustainability, the QHT Boiler stands out as a modern solution for diverse heating needs. Whether for residential or commercial use, it meets the demands of today’s energy-conscious consumers.