Seagate ST36530N/W/WC manual Interconnect characteristics for single-ended I/O circuits

Page 28

26

Medalist Pro Installation Guide, Rev. B

Figures 3a, 3b, 3c, and 3d show typical drive connections. The following table lists the maximum cable lengths and number of devices with single-ended I/O circuits allowed on a daisy-chain cable for <10 and <20 M transfers/sec I/O data transfer rates.

Table 4a. Interconnect characteristics for single-ended I/O circuits

 

Maximum distance between

Number of attached SCSI

terminators (meters) [1] [3]

devices

Fast-5

Fast-10

Fast-20

Fast-40

 

 

 

 

 

1 to 4 maximum capacitance

6

3

3

N/A

(25pF) SCSI devices

 

 

 

 

 

 

 

 

 

5 to 8 maximum capacitance

6

3

1.5

N/A

(25pF) SCSI devices

 

 

 

 

 

 

 

 

 

9 to 16 maximum capacitance

6

3

[2]

N/A

(25pF) SCSI devices

 

 

 

 

 

 

 

 

 

[1]For environments where all elements of the bus (cables, device inter- faces, environmental noise and other parameters) are controlled to be better than minimally required, it may be possible to extend the path length and device count.

[2]Extending the device count beyond eight requires specification con- trol beyond the minimum specified in the ANSI T10/1302D docu- ment. It is recommended that the devices be uniformly spaced between terminators with the end devices located as close as possi- ble to the terminators.

[3]Values specified by data rate shall apply even if a slower data rate is negotiated.

Image 28
Contents ST39140N/W/WC/LW/LC Contents Handling precautions PrefaceElectrostatic discharge protection Important safety information and precautions Medalist Pro Installation Guide, Rev. B Wichtige Sicherheitshinweise Medalist Pro Installation Guide, Rev. B Page Electromagnetic susceptibility Regulatory agency complianceElectromagnetic compliance Electromagnetic compliance for the European Union Australian C-TickSeagate Technology support services Presales Support Customer Service CSO European Support Services Africa/Middle East Support Services SeaFAX General description Drive characteristics RPMDCX DC power requirements Amps for LW/LC Models ST39140 ST34520Medalist Pro Installation Guide, Rev. B Dimensions of the drive General information Drive modelsScsi ID jumpers Drive termination Terminator power Circuits and data path widthsInterconnect characteristics for single-ended I/O circuits Interconnect characteristics for LVD I/O circuits Fifty pin I/O connection to drive Multiple drive connection to host adapter Multiple-drive connection to host adapter Medalist Pro Installation Guide, Rev. B Providing adequate cooling Kühlung des Systems Suggested air flow Abbildung 4. Empfohlener Luftstromverlauf Mounting the drive and connecting cables Installation des Laufwerkes und Anschluß der KabelMedalist Pro Installation Guide, Rev. B DC power connector Abbildung 5. Gleichstromanschluß Hinweis Page Mounting configuration dimensions Formatting the drive Quick reference desktop system notesSetting the Scsi ID jumpers Setting the Scsi ID on model N drivesTerminating the drive Terminating the driveSetting terminator power jumpers Other applicable jumper options Additional jumper optionsLW drives Host Alternate Enable Scsi terminator Disable Scsi terminator Model only Terminator power Additional jumper options for W/LW drives Additional jumper option for LW drives WC/LC drives Applicable jumper options Jumper optionsLC drives Additional jumper options for LC drives Page