Effective Gripping Force

Angular Style Air Gripper

Toggle Type Series MHT2

Workpiece gripping point should be within the range indicated in the graph.

Gripping point distance (mm)

L

Indication of effective gripping force The effective gripping force shown in the graphs to the right is expressed as F, which is the thrust of one finger, when both fingers and attachments are in full contact with the work- piece as shown in the figure below.

Precautions

Be sure to read before handling. Refer to pages 12-15-3 to 12-15-4 for Safety Instructions and Common Precautions on the product mentioned in this catalog, and refer to pages 12-1-4 to 12-1-6 for Precautions on every series.

Warning

Maintenance

If a workpiece is to be gripped by using the toggle, make sure to periodically check that the workpiece has not shifted during the acceleration of the movement.

If the workpiece is not gripped in a stable manner, it could shift or drop and create a dangerous situation.

If the workpiece is not gripped in a stable manner, use shims on the attachment to adjust the gripped.

To verify the gripping condition or to make any adjustments, make sure to do so in an area where the air gripper or the workpiece will not fall.

MHT2-32D

Gripping force (N)

MHT2-40D

Gripping force (N)

MHT2-50D

Gripping force (N)

MHT2-63D

Gripping force (N)

L = 100 mm

Pressure 0.6 MPa

0.4 MPa

0.2 MPa

Opening/Closing angle (Both sides)

L = 120 mm

Pressure 0.6 MPa

0.4 MPa

0.2 MPa

Opening/Closing angle (Both sides)

L = 150 mm

Pressure 0.6 MPa

0.4 MPa

0.2 MPa

Opening/Closing angle (Both sides)

L = 180 mm

Pressure 0.6 MPa

0.4 MPa

0.2 MPa

Opening/Closing angle (Both sides)

MHZ

MHF

MHL

MHR

MHK

MHS

MHC

MHT

MHY

MHW

MRHQ

Misc.

D-

20-

12-9-3

Image 3
Contents Series MHT2 Model/Specifications Switch Mounting Bracket Part NoMHT2-63D MHT2-32DMHT2-40D MHT2-50DSeries MHT2 MHT2-50D Construction Mounting of Auto Switch Auto Switch Hysteresis Series MHZ2/MHZJ2/MHK2/MHKL2/MHC2/MHT2 MHF MHL MHR MHK MHS MHC MHT MHY MHW Mrhq Safety Instructions Common Precautions Quality Assurance Information ISO 9001, ISO Low Voltage Directive CE MarkEC Directives and Pneumatic Components Machinery Directive Electromagnetic Compatibility EMC DirectiveTssa Mccr Registration Products CSA Standards & UL StandardsSMC’s Global Service Network SMC’s Global Service Network