System Works 99101100 manual Section IV. Installation, Inlet

Page 4

6.Insert the Check Valve into the outlet port

approximately 3/4" to 1" deep making sure the rubber diaphragm facing outward (towards you), see Diagram 1.

7.

Reconnect the return hose to the outlet port and

 

 

 

tighten the union fitting.

 

 

8.

Replace the drain cap.

 

 

 

 

9.

Remove the rag from the skimmer or open the

 

 

 

valve on the suction line.

 

 

10.

If the return line was plugged, unplug it at this time.

Diagram1.

 

 

11.With the High Flow™ manual air relief valve in the

open position, start the filter pump, after a steady stream of water appears close the High Flow™ manual air relief valve.

12.Your system is now in operating order.

SECTION IV. INSTALLATION

To install this filter system, you will need the following simple tools - a screwdriver, pliers, and wrench.

1.Carefully remove the equipment from the carton and check for any evidence of damage due to rough handling or shipping. If any of the equipment is damaged, immediately notify the organization where the equipment was purchased.

2.Position a tee-nut on the boss underneath the skid base. Screw a bolt with washer into the tee-nut from the top of the base. Continue screwing the bolt into the tee-nut until the tee-nut is flush with the boss. Unscrew the bolt. Repeat procedure for the remaining bosses.

3.This filter should be mounted on a level concrete slab, preferably concrete poured in a form or on a platform constructed of concrete block or brick.

4. Depending upon how your skimmer is positioned in

DetailC

 

relationship to the return fitting, see Diagram 3, either

Detail D

right or left of the skimmer, position the mounting base

 

accordingly; see Diagram 3. Position the filter tank on

 

the mounting base so the filter inlet port is oriented

 

toward the pump similar to Diagram 2. Secure the filter

 

to the mounting base using two bolt fasteners. Place

DetailB

the pump on the mounting base; see Diagram 2.

 

Loosely attach the pump connector, see Detail A, to the

inlet

pump and filter. This will align the pump to the correct

 

set of mounting holes. Secure the pump to the base

 

using two bolt fasteners. Tighten the union fittings on

 

the plumbing connector by hand until tight. If water

 

leakage occurs at these connections, adjust

Detail A

connections with a wrench making sure not to exceed 1/

 

4 of a turn.

Diagram2.

P/N 99101100

4

REV. F 5-1-01

Image 4
Contents Table of Contents Section I. Pump Safety Instructions Section II. HOW Your Filter WorksReadandfollowallinstructions SavetheseinstructionsSection III. Check Valve Installation Instructions InstallationSection IV. Installation InletPool Section VI. Cleaning the Filter Section V. Initial START-UP and Restart InstructionsDo not USE a PETROLEUM-BASE Lubricant on the O-RING Section VIII. Cleaning the High Flow Manual AIR Relief Valve Section VII. WinterizingthefilterSection Trouble Shooting Section Pump InstructionsTheelectricmotor Section XI. Technical Data Filter and Tank Replacement PartsMaxim Pump Dynamo Pump Section XI. Technical Data Dynamo Pump REV. F

99101100 specifications

System Works 99101100 is a comprehensive software suite designed for users seeking an integrated solution for system optimization, maintenance, and productivity enhancements. This all-in-one tool serves as a reliable companion, ensuring that personal computers run at peak performance through a variety of advanced features and technologies.

One of the primary characteristics of System Works 99101100 is its intuitive user interface that simplifies navigation, allowing users of all levels to access the tools they need quickly. The suite includes a powerful disk management utility that optimizes disk performance by defragmenting and reorganizing data on hard drives. This ensures faster data access and improved efficiency, prolonging the lifespan of storage devices.

The suite also incorporates effective virus protection and security features. With built-in antivirus capabilities, System Works 99101100 scans for and eliminates potential threats before they can compromise system integrity. Regular updates ensure that the software remains current with the latest security definitions, giving users peace of mind while browsing the internet or downloading files.

Another noteworthy feature is the system recovery tool, which assists users in restoring their systems to a previous state in case of failure or unwanted changes. This functionality is crucial in today's computing environment, where data loss can occur due to various unforeseen events. System Works 99101100 helps safeguard important files, ensuring that critical data remains recoverable.

In terms of performance tuning, the suite includes tools designed to optimize startup programs, manage system resources, and configure system settings. This level of customization allows users to tailor their computing experience according to their specific needs, enhancing productivity by streamlining workflows.

Additionally, System Works 99101100 is equipped with a detailed reporting system that offers insights into system health and performance benchmarks. Users can track progress over time and make informed decisions about necessary maintenance activities.

In conclusion, System Works 99101100 presents an array of features that focus on enhancing user experience by providing efficient solutions for system maintenance, security, and optimization. Its combination of usability, cutting-edge technology, and comprehensive functionality makes it a standout choice for anyone looking to improve their computing environment. With such a robust toolkit, users can enjoy a seamless and productive experience, free from common technical hindrances.