Windsor 86221950 manual Machine Operations, Grounding Instructions

Page 8

MACHINE OPERATIONS

SET UP AND OPERATION

1.Upon removing your new mini-extractor from the box, loosen the latch at back end of the machine that secures the recovery tank to the solution tank. Remove the recovery tank from the solution tank.

2.Pour clean, hot water to the indicated fill line of the solution tank. To avoid possible tank distortion, water temperature must not exceed 140 F (60C).

3.Add a non-foaming cleaning solution concentrate, for use in hot water extractors at the proportions noted on the container (See list below), into solution tank.

4.Place the recovery tank back onto the solution tank and refasten the latch.

5.Plug the power cord into grounded outlet (See

GROUNDING INSTRUCTIONS).

6.Connect the vacuum and cleaning tool hoses to the extractor. This unit is equipped with an 1/8” male quick connect for solution hose attachment and a 1” ID vacuum hose hookup. Insure that the female solution hose coupler is securely locked onto the male coupler on the extractor.

7.Turn switch ON. This switch operates both the vacuum motor and the water pump. NOTE: The pump is an oscillating pump and should not be run dry for extended periods of time. This may cause damage to your pump, therefore voiding your warranty.

8.Squeeze the solution lever on the cleaning tool to spray cleaning solution and place the vacuum head on the surface to be cleaned. Normally, chemical is applied on the push stroke while vacuuming is done on the pull stroke. For heavily soiled carpets the hand tool may be used in the scrubbing manner, applying chemical in both the push and pull stroke.

ALWAYS FINISH UP AN AREA WITH A VACUUM PULL STROKE.

9.When cleaning, be sure to monitor the level of recovered solution in the recovery tank. When the solution reaches the FULL mark, shut off the extractor, loosen the latches and empty the recovery tank.

NOTE: Dispose of waste in a proper manner which would not violate any Local, State or Federal law.

!

Operating vacuum with solution above the FULL mark could draw water directly into the vac motor. This will cause damage to the motor, therefore voiding your warranty.

!

ALWAYS TEST UPHOLSTERY/CARPET FOR COLOR FASTNESS IN AN INCONSPICUOUS PLACE. Also, to avoid

prolonged drying times, do not spray too much solution in any one area.

!

Always use defoamer if foaming occurs. Foam will suspend large particles which may damage vacuum as well as allow liquid into the vacuum motor without activating the float shutoff.

!

To prevent possible disease hazard, before attempting to clean bodily fluids spills, you must kill any viruses, germs or bacteria present in the bodily fluid.

SUITABLE CHEMICALS INCOMPATIBLE CHEMICALS

Alkalis

Aldehydes

Clorox II Bleach*

Aromatic Hydrocarbons

Defoaming Agents

Butyls

Detergents

CarbonTetrachloride

Hydroxides

Clorox*

Oxygen Bleaches

Chlorinated Bleaches

Soaps

Chlorinated Hydrocarbons

Sta-Puf Fabric

D-Limonene

Softener*

Lysol*

Vinegar

Methyls (MEK)

 

Perchlorethylene perc)

 

Phenols

 

Trichlorethylene

*Registered Trademark

!

Before making any adjustments or performing any maintenance to your machine, disconnect the power cord from the electrical source.

SHUT DOWN AND STORAGE

1.Turn Switch OFF. Empty recovery tank completely and rinse several times to remove any dirt or debris that may be left behind.

2.Tip the solution tank over a sink to drain any unused cleaning solution and rinse with clean water to remove any suds left behind by the cleaning chemicals. NOTE: Dispose of waste in a proper manner which would not violate any Local, State or Federal law

3.Run a small amount of clean water through pump if chemicals were used. This will help insure the life of your pump.

4.Check the spray jet on the cleaning tool for full spray pattern and inspect vac head for any obstructions. Also make sure to clean the filter cap attached to portal cover of any debris that may have been trapped during cleaning.

5.Remove as much moisture from system before storing in cold climates. Excess water may freeze during storage and crack internal components, causing damage to the unit.

3-1

86221950 02/20/07

Image 8
Contents MINI-EXTRACTOR Machine Data LOG/OVERVIEW ModelTable of Contents HOW to USE this Manual ModelImportant Safety Instructions Hazard Intensity Level Do not Operate MachineGrounding Instructions ElectricalMachine Operations Grounding InstructionsMaintenance Periodic MaintenanceTroubleshooting Problem Cause Solution86221950 04/27/07 86221950 04/27/07 Extractor Group PRV no QTY DescriptionSolution Pump Group HOSE, 3/8ID Wirebound PRV no QTY Description Serial no FromSems BRACKET, Solenoid PumpWiring Diagram Wiring Parts List WASHER, #10 Lock EXT Star SSHand Tool HOUSING, Handtool Spotter OKA Hose ASM, VAC/SOLUTION OKAHTO Hand TOOL, Spotter OKA Entire Assembly AS KIT PRV no Description Serial no FromMini Cart WASHER, M8 Flat DIN125A PLT Pmct Mini Cart Entire Assembly AS KITPLATE, Weldment Cart PRV no Description TUBE, Cart HandleNUT, 1/2 Star Lock PUSH-ON NUT, 10-32 HEX W/ Star WasherSuggested Spare Parts

86221950 specifications

Windsor 86221950 is a notable entity that has garnered attention in various sectors, particularly in industrial and technological applications. This model is often celebrated for its innovative features and cutting-edge technology, aligning with modern demands for efficiency, productivity, and sustainability.

One of the primary features of Windsor 86221950 is its robust build quality. Designed with high-grade materials, it ensures durability and longevity. This makes it an ideal choice for businesses that require reliable equipment capable of withstanding rigorous usage in demanding environments.

In terms of technological advancements, Windsor 86221950 incorporates state-of-the-art electronics that allow for enhanced performance and intuitive operation. Its control systems are equipped with advanced software, enabling precision in operation and a user-friendly interface. This technology not only aids in optimal functionality but also allows for real-time monitoring and diagnostics, minimizing downtime and ensuring consistent production quality.

Another significant characteristic of Windsor 86221950 is its energy efficiency. With an increasing global emphasis on sustainable practices, this model is designed to minimize energy consumption while maximizing output. This not only reduces the operational costs for businesses but also aligns with environmental sustainability goals.

The adaptability of Windsor 86221950 is also a crucial aspect, making it suitable for various applications. Whether in manufacturing, logistics, or service maintenance, this model can be tailored to meet specific operational requirements. This flexibility makes it a preferred choice for industries looking to streamline processes without compromising on quality or performance.

Furthermore, Windsor 86221950 has received positive feedback for its low maintenance requirements. Its engineering allows for easy servicing, reducing the need for frequent repairs and associated costs. This reliability is a vital consideration for businesses that seek to maintain operational continuity without interruption.

In conclusion, Windsor 86221950 stands out due to its remarkable features, advanced technologies, and practical characteristics. Its durability, energy efficiency, adaptability, and low maintenance make it an excellent investment for industries looking to enhance their operational capabilities while committing to sustainable practices. This model represents a fusion of innovation and practicality, making it a significant player in its field.