MACHINE TROUBLESHOOTING

PROBLEM

CAUSE

 

Poor or no water pick-up

Squeegee out of

 

 

adjustment

 

 

Debris caught on squeegee

 

 

Worn squeegee blades

 

 

 

 

 

Vacuum hose clogged

 

 

 

 

 

Vacuum hose disconnected

 

 

from squeegee or recovery

 

 

tank

 

 

Vacuum hose damaged

 

 

Recovery tank not sealed

 

 

 

 

 

Foam filling recovery tank

 

 

 

 

Vacuum motor does not run, or

Recovery tank full

 

runs slowly

 

 

 

Recovery tank float system

 

 

dirty

 

 

Circuit breaker tripped

 

 

Loose connection

 

 

 

 

 

Faulty vacuum switch

 

 

Worn vacuum motor

 

 

brushes

 

Poor scrubbing performance

Debris caught in scrub

 

 

brushes

 

 

Worn brushes or pads

 

 

Improper detergent, brush

 

 

or pad used

 

 

Low scrub brush down

 

 

pressure

 

 

Low battery charge

 

Brush motors do not run, or runs

Circuit breaker(s) tripped

 

slowly

 

 

 

Loose connection

 

 

 

 

 

Faulty brush motor

 

 

contactor

 

 

Worn brush motor brushes

 

 

 

 

CUTTER 24V 86039070 04/10/07

4-13

Image 31
Contents Walk Behind Scrubber Your Dealer Machine Data LOG/OVERVIEWOverview Table of Contents Model HOW to USE this ManualRead ALL Instructions Before Using this Machine Important Safety InstructionsHazard Intensity Level Hazard Intensity LevelSafety Label Location DIMENSION/CAPACITY Technical SpecificationsMeasure Special NotesHOW the Machine Works Components Controls Emergency SHUT-OFF Switch Optional KEY SwitchBrush Switch Squeegee Lift Lever Solution Control KnobVacuum Switch Squeegee Pitch Adjustment KnobHour Meter Optional Parking Brake OptionalPRE-RUN Machine Inspection Emergency Stop ProceduresFilling Solution Tank Machine OperationTo Begin Scrubbing Normal ScrubbingTo Stop Scrubbing Double Scrub Emptying and Cleaning TanksMaintenance Daily Weekly Monthly Maintenance Service ScheduleHRS Maintenance Batteries Battery MaintenanceChecking Gravity Checking Battery Specific Gravity To Charge the BatteriesFront of Machine Changing BatteriesTo Replace or Rotate Rear Squeegee Blades Adjusting SqueegeeTo Remove Squeegee Assembly Squeegee BladesTo Adjust Amount of Rear Squeegee Deflection To Adjust Squeegee PitchTo Replace AQUA-MIZER Squeegee Blades Uncoated Floors Replacing or Installing Scrub BrushesRecovery Tank Float SHUT-OFF Scrub BrushesChanging Brush Motors Solution StrainerBrush Motor Carbon Brush Replacement Brush MotorBrush Shrouds & Brush Skirts Traction Motor Carbon Brush ReplacementTraction Motor Circuit BreakersChanging Vacuum Motor Vacuum MotorRecommended Greasing Problem Cause Machine TroubleshootingProblem Cause Solution This page Left Blank Intentionally