Windsor SCC264, SC264, 10052250, 10052210 manual Changing Vacuum Motor

Page 29

11. VACUUM MOTOR

(Refer to the Vacuum Group in the parts section of manual)

!

Do not use a pressure washer to clean around the vacuum motors. Use tap pressure only. Care must be taken so that water is not directed into vacuum motor air intakes.

CHANGING VACUUM MOTOR

1.Disconnect batteries from machine.

2.Remove front cover.

3.Disconnect electrical connector to the vacuum motor.

4.Loosen clamp and disconnect hose from vacuum intake.

5.Remove vacuum motor mounting bracket bolts.

6.Remove vacuum motor from mounting bracket.

7.Reverse steps to install.

Vacuum Motor Carbon Brushes Replacement (Windsor)

End Cap

Carbon

Brushes

If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.

Important:

These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely.

38 [9.5mm]

Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long.

MAINTENANCE

Vacuum Motor Carbon Brushes Replacement (Ametek)

End Cap

Carbon

Brushes

If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.

Note: Place stop in groove.

Important:

These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely.

3/8 (9.5mm)

Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long.

CUTTER 24V 86039070 04/10/07

4-11

Image 29
Contents Walk Behind Scrubber Overview Machine Data LOG/OVERVIEWYour Dealer Table of Contents Model HOW to USE this ManualRead ALL Instructions Before Using this Machine Important Safety InstructionsHazard Intensity Level Hazard Intensity LevelSafety Label Location DIMENSION/CAPACITY Technical SpecificationsMeasure Special NotesHOW the Machine Works Components Controls Brush Switch KEY SwitchEmergency SHUT-OFF Switch Optional Vacuum Switch Solution Control KnobSqueegee Pitch Adjustment Knob Squeegee Lift LeverHour Meter Optional Parking Brake OptionalFilling Solution Tank Emergency Stop ProceduresMachine Operation PRE-RUN Machine InspectionTo Stop Scrubbing Normal ScrubbingTo Begin Scrubbing Double Scrub Emptying and Cleaning TanksHRS Maintenance Service ScheduleMaintenance Daily Weekly Monthly Maintenance Batteries Battery MaintenanceChecking Gravity Checking Battery Specific Gravity To Charge the BatteriesFront of Machine Changing BatteriesTo Remove Squeegee Assembly Adjusting SqueegeeSqueegee Blades To Replace or Rotate Rear Squeegee BladesTo Replace AQUA-MIZER Squeegee Blades To Adjust Squeegee PitchTo Adjust Amount of Rear Squeegee Deflection Recovery Tank Float SHUT-OFF Replacing or Installing Scrub BrushesScrub Brushes Uncoated FloorsBrush Motor Carbon Brush Replacement Solution StrainerBrush Motor Changing Brush MotorsTraction Motor Traction Motor Carbon Brush ReplacementCircuit Breakers Brush Shrouds & Brush SkirtsChanging Vacuum Motor Vacuum MotorRecommended Greasing Problem Cause Machine TroubleshootingProblem Cause Solution This page Left Blank Intentionally