CONTROLS

7.BRUSH PRESSURE LEVER

Adjusts the amount of brush pressure to the floor by raising or lowering the scrub deck.

To apply brush pressure, lower brush pressure lever to floating position.

To apply additional pressure, place lever in restricted position. Lock the lever into the lower notch. Push the lever forward to move in a downward motion. Pull back on lever and release for floating position.

To decrease brush pressure, raise lever to up position.

8.SOLUTION CONTROL KNOB

Controls solution flow to scrub deck. To increase flow, rotate knob clockwise.

To decrease flow, rotate knob counterclockwise.

If the brush motors are turned off or the propel control levers are in neutral, the flow is automatically interrupted until the motors are turned on again. This feature prevents unintentional draining of the solution tank and allows the operator to adjust the solution flow to the scrub deck without resetting each time the scrubbing operation is interrupted.

9.VACUUM SWITCH

Controls the vacuum motor.

To start vacuum motor, press the bottom of the switch. To stop vacuum motor, press the top of the switch.

10.SQUEEGEE LIFT LEVER

Raises and lowers the squeegee.

To lower the squeegee, lift the lever from its raised position.

To raise the squeegee, lift the lever from its lowered position.

11.SQUEEGEE PITCH ADJUSTMENT KNOB

Adjusts the deflection at the ends of the squeegee.

To increase squeegee blade deflection at the ends, turn knob counterclockwise.

To decrease squeegee blade deflection at the ends, turn knob clockwise.

12.SQUEEGEE DEFLECTION ADJUSTMENT KNOBS

Adjusts the deflection along the entire length of the squeegee.

To increase squeegee blade deflection along the entire length, turn the two knobs at the squeegee ends counter- clockwise.

To decrease squeegee blade deflection along the entire length, turn the two knobs at the squeegee ends clockwise.

3-7

CUTTER 24V 86039070 04/10/07

Image 14
Contents Walk Behind Scrubber Overview Machine Data LOG/OVERVIEWYour Dealer Table of Contents HOW to USE this Manual ModelImportant Safety Instructions Read ALL Instructions Before Using this MachineHazard Intensity Level Hazard Intensity LevelSafety Label Location Technical Specifications DIMENSION/CAPACITYSpecial Notes MeasureHOW the Machine Works Components Controls Brush Switch KEY SwitchEmergency SHUT-OFF Switch Optional Squeegee Pitch Adjustment Knob Solution Control KnobVacuum Switch Squeegee Lift LeverParking Brake Optional Hour Meter OptionalMachine Operation Emergency Stop ProceduresFilling Solution Tank PRE-RUN Machine InspectionTo Stop Scrubbing Normal ScrubbingTo Begin Scrubbing Emptying and Cleaning Tanks Double ScrubHRS Maintenance Service ScheduleMaintenance Daily Weekly Monthly Maintenance Battery Maintenance BatteriesChecking Battery Specific Gravity To Charge the Batteries Checking GravityChanging Batteries Front of MachineSqueegee Blades Adjusting SqueegeeTo Remove Squeegee Assembly To Replace or Rotate Rear Squeegee BladesTo Replace AQUA-MIZER Squeegee Blades To Adjust Squeegee PitchTo Adjust Amount of Rear Squeegee Deflection Scrub Brushes Replacing or Installing Scrub BrushesRecovery Tank Float SHUT-OFF Uncoated FloorsBrush Motor Solution StrainerBrush Motor Carbon Brush Replacement Changing Brush MotorsCircuit Breakers Traction Motor Carbon Brush ReplacementTraction Motor Brush Shrouds & Brush SkirtsVacuum Motor Changing Vacuum MotorRecommended Greasing Machine Troubleshooting Problem CauseProblem Cause Solution This page Left Blank Intentionally