Testing and Adjustment Procedure

Testing and Adjustment Procedure

The fully installed system is shown below To test that the classroom audio is muted when a PA system announcement (page) occurs:

1. Turn the classroom audio on.

2. Speak into the PA system microphone. The classroom audio should be muted while the PA system page occurs and be restored when the page ends.

3. If the Priority Page Controller fails to mute the classroom audio during a page, turn the Sensitivity adjustment, on the rear panel of the controller, clockwise.

4. If the classroom audio is muted without a page occurring, turn the Sensitivity adjustment counterclockwise

5. If the classroom audio is muted for too long a time after a page, or is restored too early, check the Time DIP switch settings. A short time delay is necessary so that if the PA system announcer pauses briefly during the announcement, the classroom audio is not restored prematurely. Set the switches so that the output relay will remain closed for a set time after a PA announcement has ended.

TIME SENSITIVITY

ON

1 2

Adjusting sensitivity knob:

Clockwise to increase

Counterclockwise to decrease

3/ 4 Sensitivity knob adjustment

TIME

 

TIME

 

ON

= 2.0 sec (default)

ON

= 4.0 sec

 

 

 

 

1

2

 

1

2

 

TIME

= 6.0 sec

TIME

= 8.0 sec

ON

ON

1

2

 

1

2

 

5Priority Page Controller Time DIP switch settings

From Classroom

 

Paging System

 

Page

Ceiling Mounted

Paging Speaker

Sensor

 

PV SI 3C LP

Ceiling

Speakers

Extron

 

PVS 204SA

 

Twisted Pair

 

Switcher

Remote

 

Relay

Vol/Mute

Control

Output

 

Extron

PPC 25

Priority Page

Controller

PoleVault Systems Installation • Optional Accessory Installation 2-33

Page 45
Image 45
Extron electronic 400 Testing and Adjustment Procedure, 3 / 4 Sensitivity knob adjustment, = 2.0 sec default, = 6.0 sec