Extron electronic 200 Viewing obstructions, c. Location of MediaLink Controller and Wall Plates

Models: 200 300 400 PVS 400

1 50
Download 50 pages 35.12 Kb
Page 7
Image 7
•Viewing obstructions

Viewing obstructions

Pillars, furniture etc., window locations for glare reduction, obstructions between projector and screen

c.Location of MediaLink Controller and Wall Plates

Forward and side reach (for full details refer to a copy of "ADA Standards for Accessible Design", "Section 4-2", "Space Allowance and Reach Ranges")

48"

(122 cm)

Max

54"

(137 cm)

Max

15" c.Location of MediaLink Controller and Wall Plates (38 cm)

Min

10"

(25.5 cm) •Location of source devices Max

9"

(23 cm)

Min

30"

(76 cm)

 

24"

30"

 

(61 cm)

(76 cm)

46"

 

 

(117 cm)

34"

 

Max

 

(86.5 cm)

 

 

 

High Forward Reach Limits (ADA referenced figure 5a, redrawn)

High / Low Side Reach Limits

Max Side Reach over Obstruction Limits

(ADA referenced figure 6b, redrawn)

(ADA referenced figure 6c, redrawn)

ADA high/low forward, side and over obstruction reach limit requirements

Location of source devices

Desk, table, or rack mounted, proximity to proposed transmitter location (wall, podium, or furniture)

Cabling obstacles

Studs, utility pipes, power supply location (raceway installation needed?)

Network drop for MediaLink Controller

Wall or floor cabled

d. Type and location of the speakers

Speaker type based on room ceiling and wall type

Total number and spacing of speakers

Based on ceiling height and room size

Audience seating and room acoustics

Desired evenness of sound coverage and ambient noise level compensation

Windows

TV / VCR / DVD Inputs

Student Desks

Each speaker covers one-fourth of listening area.

Speaker

Location

Projector/Switcher

Location

MLC Controller

Location

Teacher’s

Desk

PVT A/V Wallplate

Screen/White board

Location

Location

Example classroom with four speaker installation

PoleVault Systems Installation • Introduction — Planning

1-5

Page 7
Image 7
Extron electronic 200, 400 Viewing obstructions, c. Location of MediaLink Controller and Wall Plates, Cabling obstacles