Windsor 10080220, CDT7 manual Troubleshooting Chart, Problem, Cause, Solution

Page 24
TROUBLESHOOTING CHART

TROUBLESHOOTING CHART

PROBLEM

CAUSE

SOLUTION

No Power, Nothing

Is the cord plugged in.

Plug in cord.

Circuit breaker tripped in building.

Reset breaker.

Runs

Faulty switch.

Call for service.

 

 

Faulty power cord or pigtail.

Call for service.

Vacuum Motor Will Not

Vacuum circuit breaker tripped.

Reset breaker.

Run

.Faulty main vacuum switch.

Call for service.

 

Loose wiring.

Call for service.

 

Faulty vac motor.

Call for service.

 

Debris lodged in vac shoe.

Remove debris from vac shoe.

Vacuum Motor Runs

 

 

But

.Dome gasket defective or missing.

Replace as necessary.

Suction Is Poor

Vacuum hose cracked or hose cuff loose.

Replace or repair as necessary.

 

Recovery tank full / float ball stuck in the

Turn off vac motor. Drain and rinse

 

up position.

recovery tank.

Poor Or No Water Flow

Main pump switch off.

Turn on.

(Carpet Is Streaky)

 

 

 

Jets clogged or missing.

Clean using a vinegar /water solution or

 

 

replace.

 

Solution filter clogged.

Drain solution tank and clean solution

 

 

filter.

 

Faulty solenoid.

Call for service.

Brush Does Not Spin

Brush switch off.

Turn on brush switch.

Brush circuit breaker tripped.

Reset circuit breaker.

 

 

Brush belt broken.

Replace as necessary.

 

Faulty brush motor.

Call for service.

4-7

CADET 86038220 03/16/07

Image 24
Contents Operating Instructions MODEL: CDT7CARPET EXTRACTOR 86038220 09/27/07 PRV NO.MACHINE DATA LOG/OVERVIEW MODEL _______________________________________DATE OF PURCHASE __________________________ SERIAL NUMBER ______________________________TABLE OF CONTENTS HOW TO USE THIS MANUALSAFETY OPERATIONSHOW TO USE THIS MANUAL SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS HAZARD INTENSITY LEVEL FOR SAFETYWHEN SERVICING MACHINE HAZARD INTENSITY LEVELGROUNDING INSTRUCTIONS ELECTRICALGROUNDING INSTRUCTIONS TECHNICAL SPECIFICATIONS POWER TYPEGENERAL DIMENSIONS/WEIGHT CONTROLS/COMPONENT LOCATIONS 5.Vacuum Motor Switch. Turns on vacuum motor1 6 2 5 4 86.Recovery Tank Dome 8.Brush Housing 9.Front Lifting Handle10.Cleaning Solution Filter CONTROLS/COMPONENT LOCATIONS1.Solution Intake Cover 2.Vacuum Intake Cover 3.Float Shut-Off 4.Clean-OutOpening 5.Pour SpoutCONTROLS/COMPONENT LOCATIONS 6.Lift HandleFILLING OPERATIONS CADET 86038220 03/16/07RECOVERY TANK SOLUTION TANK FILL LINE FILLING THE CADETOPERATIONS INCORRECTOPERATIONS INTERMITTENT CONTINUOUSCLEANING PROCEDURE 1ft 30cm1in 25mm CLEANING PROCEDURE STEPACCESSORY TOOL USAGE 3-10PUMPVACUUM ONON OFF MAINTENANCE SERVICE SCHEDULE MAINTENANCEDAILY WEEKLYMAINTENANCE PERIODIC MAINTENANCEDAILY / REGULAR MAINTENANCE MAINTENANCE ONLY QUALIFIED WARNING: MAINTENANCEVacuum Motor Carbon Brushes Replacement Windsor Vacuum Motor Carbon Brushes Replacement AmetekMAINTENANCE ONLY QUALIFIED WARNING: MAINTENANCE PERSONNEL ARETO PERFORM THE FOLLOWING REPAIRS BELT REPLACEMENT MAINTENANCE SOLUTION PUMP REPLACEMENTWIRING DIAGRAM 8626845086268830 86266890 PRV NO. 86004480 PRV NO.TROUBLESHOOTING CHART PROBLEMSOLUTION CAUSETHIS PAGE INTENTIONALLY LEFT BLANK MAINTENANCEFRAME ASSEMBLY FRAME ASSEMBLY PART NOBRUSH ASSEMBLY CADET 86038220 03/16/07BRUSH ASSEMBLY PART NOPUMP ASSEMBLY PUMP ASSEMBLY PART NOFROM SERIAL NO: PUMP ASSEMBLYSEE SOLUTION 8 4 10 23PUMP ASSEMBLY PART NOVACUUM SHOE ASSEMBLY CADET 86038220 03/16/075-10 VACUUM SHOE ASSEMBLYCONTROL PANEL ASSEMBLY 5-115-12 CONTROL PANEL ASSEMBLYPART NO SOLUTION TANK ASSEMBLY 5-135-14 SOLUTION TANK ASSEMBLYPART NO RECOVERY TANK ASSEMBLY 5-155-16 RECOVERY TANK ASSEMBLYPART NO SUGGESTED SPARE PARTS 5-17