Vinotemp WM 6500SSH, 8500SSH, 4500SSH, WM 2500SSH manual Troubleshooting

Page 13

Troubleshooting

This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive

Troubleshooting Chart

Complaint

 

Possible Causes

 

Response

1. Unit not running

 

 

 

a.

Power cord unplugged

a.

Check for power cord plug

 

b.

No power to unit

b.

Check power at receptacle & fuses

 

c.

Temperature setting high

c.

Lower temperature setting

 

d.

Low voltage.

d.

Contact an authorized electrician

 

e.

Incorrect or loose wirings.

e.

Check all wirings and connections

 

f.

Defrost light blinking

f.

Under defrost

 

g.

Running light blinking

g.

Call service for failed components

 

 

 

 

2. Compressor

stopping and starting but short

running time

 

a.

Incorrect temperature setting

a.

Set 55 to 60 °F

 

b.

Incorrect voltage

b.

Check for voltage

 

c.

Failed thermistor

c.

Check thermistor by placing it in ice

 

d.

Failed components

 

water and measuring resistance

 

d.

Check compressor windings, start

 

e.

Improper condenser airflow

 

relay and overload protector.

 

e.

Check for condenser fan

 

f.

Dirty condenser

f.

Clean condenser

 

g.

Overcharge of refrigerant

g.

Call service for removing refrigerant

 

h.

Discharge or suction pressure too

h.

Call service for OEM information

 

 

high

 

 

3. Fan motor

running but compressor not running

 

 

a.

Incorrect power supply

a.

Check for proper voltage

 

b.

Incorrect or loose wirings

b.

Check all wirings and connections

 

c.

Failed components

c.

Check start relay, start capacitor,

 

 

 

 

overload protector, compressor.

 

d.

Liquid refrigerant in the compressor

d.

Call service for OEM information.

4. Compressor

running but fan not running

 

 

 

a.

Fan blade bond

a.

Check for proper clearance

 

b.

Incorrect or loose wirings

b.

Check all wirings

 

c.

Failed motors

c.

Call service for checking open or

 

 

 

 

shorted windings

5. No cooling

but compressor and fan running

 

 

 

a.

Evaporator airflow restriction

a.

Check for airflow through evaporator

 

b.

Refrigerant leakage

b.

Check for loss of refrigerant

 

c.

Refrigeration system restriction

c.

Call service for checking restrictions

6. Temperature

too high or unit running too long

 

 

a.

Improper evaporator or condenser

a.

Check for air restrictions

 

 

airflow

 

 

 

b.

Dirty Condenser

b.

Clean condenser

 

c.

Iced evaporator

c.

Defrost and reset temperature

 

d.

Malfunctioning fans

d.

Check for both fans

 

e.

Improper seals

e.

Check for gasket and door opening

 

f.

Improper area to be cooled.

f.

Check for excessive load incorrect

 

 

 

 

installation

- 12 -

Image 13
Contents WM 2500SSH, 4500SSH WM 6500SSH, 8500SSH Winemate Split SystemTable of Contents Important Safety Information Feature Description Evaporator Unit Condensing Unit Refrigeration Installation Installation InstructionLocation Customer Wiring Electrical WiringAir Sensor Factory Wiring 2500& 4500SSH Electrical Wiring Diagram Page Temperature Setting Use & Temperature ControlSet Point Care Guide Coil CleaningMoisture Removing Troubleshooting Noisy operation House circuit trippingCustomer Support Limited Warranty WarrantyService under Warranty Limitation of Implied Warranty