Admiral AAW-05CR1FHUE, AAW-06CM1FHUE manual If storm window presents interference, fasten a

Page 9

Installation instructions

5.Install the L brackets on the outer sill with the short side of the bracket against the back of the

inner sill. Install one L bracket 7.5 to each side of the center line. See Fig. 5.

6. Carefully lift the air conditioner and slide it into

the open window. Make sure the bottom guide of

the air conditioner drops into the notches of the L

brackets. When the air conditioner drops into the L

brackets, the air conditioner will be centered in the

window opening as show in Fig. 6.

While steadying the air conditioner, carefully bring

the window sash down behind the top channel

of the air conditioner, as shown in Fig. 7.

First, fix both sides onto the window sill with two 3/4

screws and one 2/5 screw ( which is unscrewed from

each side of the unit). Then fix top channel to window

sash with one 3/4 screw and fix side curtain frames

with four 3/4 screws as shown in Fig.6.

Outer Sill

Inner Sill

 

 

 

3/4''

Screw

Center Line

 

 

3/4''

Screw

 

7.

 

Bracket

5

 

7.

 

Short Side

5

 

 

 

Fig. 5

 

 

 

 

 

 

Foam

 

3/4

screw

 

 

 

 

3/4

screw

3/4 screw

 

 

3/4

screw

 

 

2/5

screw

 

 

 

 

 

 

 

 

3/4

screw

3/4

screw

 

 

 

3/4

screw

 

7. If storm window presents interference, fasten a

2'' wide wood strip to the inner window sill across

the full width of the sill. The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference from the storm window frame, as show in Fig. 8.

Top of wood strip should be approximately 3/4'' higher than the storm window frame to help condensation to drain properly to the outside..

Fig. 6

Seal

L Bracket

About 5

Install a second wood strip (approximately 6'' long by

11/2''wide and same thickness as first strip) in the center of the outer sill flush against the back of the inner sill. Screw the L brackets into this strip.

This will raise the L bracket as shown in Fig. 8.

Fig.7

3/4''Clearance

Storm window

frame

Inner sill

Fig.8

8

Image 9
Contents Use and Care Manual Ndice Part Identification Mechanical control model IntroductionPart Identification Remote control model Electric Shock Hazard Electrical specifications See lists below Tips before installationSelect the Best Location Installation instructionsWindow opening requirements see table below Size Model Cabinet sizeWindow installation step If storm window presents interference, fasten a Mode Operating InstructionsTimer button Mode buttonIndication symbols of LED on control panel ButtonButton How to Use How to Insert the BatteriesCleaning the Air Filter Care and MaintenanceCleaning of Air Filter Air Filter RemovalProblem Possible Cause Suggested Solution Troubleshooting GuideYear Full Warranty WarrantyIdentificaci n de las Piezas Modelo Mec nico Introducci nIdentificaci n de las Piezas Modelo de Remoto controlador Peligro de Descarga El ctrica Especificaciones el ctricasConsejos antes de la instalaci n Nota Tornillo Excedente Para d Uso de ReservaPiz Cinta m trica Tijeras Nivel de carpintero Tamano Instrucciones de Instalaci nPasos para la instalaci n en ventanas Espuma Precauci N Instrucciones de Operaci nInstrucciones de Operaci n Instrucciones de Operaci n Control remoto Cuidado de Fin de Temporada Cuidado y MantenimientoGu a para la Soluci n de Problemas Garantia Version No