Electrical specifications
1.All wiring must comply with local and national electrical codes and must be installed by a licenced electrician. Once you have any questions regarding the following instructions, contact a licenced electrician.
2.Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.
3.For your safety and protection, this unit is grounded through the power cord when plugged into a matching wall outlet. If you are not sure whether your wall outlet is properly grounded, please consult a licenced electrician.
4.The wall
Electric Shock Hazard | ! |
If the air conditioner has a serial plate rating of 115 volts and up to and including 7.5 amps the unit maybe on a fuse or circuit breaker with other devices. However, the maximum amps of all devices on that fuse or circuit breaker can not exceed the amps of the fuse of circuit breaker.
If the air conditioner has a serial plate rating of 115 volts and greater than 7.5 amps it must have its own fuse or circuit breaker, and no other device or unit should be operated on the fuse or circuit breaker.
To avoid the possibility of personal injury, disconnect the power to the unit before installing or servicing.
5.The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of the unit.
| RECEPTACLE AND FUSE TYPES | |
| ||
|
| |
COOLING CAPACITY | 5K 6K | |
|
| |
RATED VOLTS | 125 | |
|
| |
AMPS | 15 | |
| ||
|
| |
WALL OUTLET |
| |
|
| |
FUSE SIZE | 15 | |
| ||
|
| |
Time Delay Fuse | Plug type | |
(or circuit breaker) | ||
| ||
|
|
Note: 5K including models
Table 1
4