Desa 5511 Bulb Installation and Relamping, Wire the Light Control, Mount the Light Control

Page 2

INSTALLATION

For easy installation, select an existing light with a wall switch for replacement.

For best performance, locate the fixture about 8 ft. (2.4 m) above the ground.

CAUTION: The sensor must be mounted below the lamp housing for wall installations.

Drill out the holes if needed to mount the backplate to the junction box.

CAUTION to avoid fire or burn hazards:

Allow fi xture to cool before touching. The bulb and fi xture operate at high temperatures.

Keep fi xture at least 2" (5 cm) from combustible materials. Do not aim at objects closer than 3 feet (1 m).

Re-lamp with type T 150W (or less) halogen 120 VAC lamp only.

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

Rotate the sensor head to-

wards the clamp screw joint.

Controls

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clamp Screw

Then rotate the sensor head counterclockwise

180° so the controls face down.

Controls

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

BULB INSTALLATION AND RELAMPING

When relamping, turn power off and let the fi xture cool.

Remove the screw that holds the glass cover shut. Remove the old bulb by pushing the bulb towards the right until the left side of the bulb is clear of the left socket.

To insert the new bulb, push the bulb into the right socket so the bulb fi ts completely into the left socket.

Check that the bulb is seated properly.

Close the glass cover. Replace screw.

WIRE THE LIGHT CONTROL

WARNING: Turn power off at circuit breaker or fuse.

Remove the existing light fi xture.

Strip about 5/8" insulation from the existing junction box wiring.

Route the Light Control’s wires through the large hole in the gasket.

Twist the junction box wires and fixture wires together as shown. Secure with wire connectors.

 

 

White to White

Black to Black

 

 

 

 

Junction box ground wire to

green ground wire on fixture. Cover Plate Gasket

MOUNT THE LIGHT CONTROL

Align the Light Control cover plate and cover plate gasket and the junction box. Insert and tighten the mounting screws.

If not installed on a weatherproof box or if an adaptor plate is used, caulk the wall plate and mounting surface with silicone weather sealant.

RIGHTWRONG

The halogen light must be mounted horizontally (+/- 4°).

2

598-1310-00

Image 2
Contents Operation Mode Switching SummaryCompact 150 Watt Motion Sensing Halogen RequirementsWire the Light Control InstallationBulb Installation and Relamping Mount the Light ControlMaximum Range Test and AdjustmentSpecifications Least SensitiveNo Service Parts Available for this Product Troubleshooting GuideTechnical Service DAY Limited WarrantyRequisitos Luz Halógena Compacta Detectora de Movimiento de 150 VatiosFuncionamiento Resumen de las modalidades del interruptorConecte EL Control DE LUZ InstalacionInstalación Y Cambio DE Bombilla Instale EL Control DE LUZAlcance Prueba Y AjusteEspecificaciones Máximo De CoberturaNo hay piezas de servicio disponibles para este producto Guia DE Investigacion DE AveriasServicio Técnico Garantía Limitada a 90 Días