TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.
NOTE: Sensor requires about 1 1/2 minutes to calibrate before it will detect motion. When fi rst turned on, wait about 1 1/2 minutes.
❒Turn the SENSITIVITY (SENS) control to the mid position and the
|
|
|
|
|
|
|
| SENS | ||||||
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MIN MAX | ||
10 5 1 TEST |
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
❒Loosen the clamp screw in the sensor ball joint and gently rotate the sensor to aim.
❒Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cover- age area.Keep the sensor at least 1" (25 mm) away from the lamps.
❒Set SENSITIVITY as needed. Too much sensitivity may increase false triggering.
❒Secure the sensor head into position by tightening the clamp screw. Do not over- tighten the screw.
Clamp |
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Bottom of Sensor
Avoid aiming the control at:
•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large,
110°
8ft.
(2.4 m)
60 ft.
(18.3 m)
Maximum Range | Maximum |
| Coverage Angle |
The control is most sensitive to motion across it.
MotionMotion
| Sensor |
Least Sensitive | Most Sensitive |
❒Set the amount of TIME the lights stay on after motion is
detected. It is selectable from 1, 5, or 10 minutes.
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 60 ft.(18.3 m);[varies with surrounding temperature]
Sensing Angle . . . . . . . Up to 110°
Electrical Load. . . . . . . Up to 150 Watts Maximum tungsten
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . 1, 5, or 10 minutes Sensitivity . . . . . . . . . . Adjustable
Replacement lamp. . . . T 150W (or less) halogen 120
VAC
DESA Specialty Products reserves the right to dis- continue products and to change specifi cations at any time without incurring any obligation to incorporate new features in products previously sold.
3 |