First Alert Carbon Monoxide Alarm If Your SMOKE/CO Alarm Sounds, If the CO Alarm Sounds

Page 3

6.Line the mounting bracket up over the plastic screw anchors.

7.Screw the mounting bracket to the ceiling

or wall through the mounting slots using the two screws provided.

8. Before attaching the Alarm to the bracket, insert the 9V battery (included) into the battery compartment. Match the terminals on the end of the battery with the termi- nals on the unit. Match “+” to “+” and “-” to “-.” Push the battery in until it snaps in securely and cannot be shaken loose. If the battery is not snapped in completely, the unit cannot receive battery power.

NOTE: The unit may beep briefly when you install the battery. This is normal.

The GREEN Light flashes about every 30 seconds when the unit is receiving battery power.

The battery door will not close unless a battery is installed. This warns you the unit will not operate without a battery.

9.Align the tabs on the base with the tabs on the mounting bracket. Turn the base until it snaps into place.

10.If the cover does not line up the way you wanted, adjust it by slowly rotating it in either direction.

11.Test the Smoke/CO Alarm. See “Weekly Testing” for details.

IF YOUR SMOKE/CO ALARM SOUNDS

WHAT TO DO FIRST–IDENTIFY THE TYPE OF ALARM

Type of Alarm

What You See and Hear

Carbon Monoxide (CO)

CO Light:

 

Flashing RED

 

Horn: 4 beeps,

 

pause, 4 beeps, pause

Smoke

Smoke Light:

 

Flashing RED

 

Horn: 3 beeps,

 

pause, 3 beeps, pause

Problem...

What You See

Indicates:

 

and Hear

You Should...

Low Battery

Battery Light:

Battery is Low:

 

Flashing GREEN

Install new 9V alkaline or

 

Horn: Chirps

lithium battery. For a list of

 

every 30 seconds

acceptable replacement

 

 

batteries, see “Regular

 

 

Maintenance.”

 

 

 

Service

Service Light:

Device is not Working

 

Flashing YELLOW

Properly: See “Testing

 

Horn: 3 quick chirps

and Maintenance”.

 

every 30 seconds

 

 

 

 

IF THE CO ALARM SOUNDS

“ALARM-MOVE TO FRESH AIR”

If you hear the alarm horn sound 4 beeps, pause, 4 beeps, pause, and the RED CO light is flashing, move everyone to a source of fresh air.

Actuation of your CO Alarm indicates the presence of carbon monoxide (CO) which can kill you. In other words, when your CO Alarm sounds, you must not ignore it!

IF THE CO ALARM SOUNDS:

1.Operate the Test/Silence button.

2.Call your emergency services, fire department or 911. Write down the number of your local emergency service here:

__________________________________________________________________

3.Immediately move to fresh air—outdoors or by an open door or window. Do a head count to check that all persons are accounted for. Do not re- enter the premises, or move away from the open door or window until the emergency services responder has arrived, the premises have been aired out, and your CO Alarm remains in its normal condition.

4.After following steps 1-3, if your CO Alarm reactivates within a 24-hour period, repeat steps 1-3 and call a qualified appliance technician to inves- tigate for sources of CO from fuel-burning equipment and appliances, and inspect for proper operation of this equipment. If problems are identified during this inspection have the equipment serviced immediately. Note any combustion equipment not inspected by the technician, and consult the manufacturers’ instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not, been operating in an attached garage or adjacent to the residence. Write down the number of a qualified appliance technician here:

__________________________________________________________________

IF THE SMOKE ALARM SOUNDS

RESPONDING TO AN ALARM

If you hear the alarm horn sound 3 beeps, pause,

3 beeps, pause and the RED SMOKE light is flash- ing, smoke has been detected. Evacuate everyone from the building.

If the unit alarms and you are not testing the unit, it is warning you of a potentially dangerous situation that requires your immediate attention. NEVER ignore any alarm. Ignoring the alarm may result in injury or death.

Never remove the batteries from a battery operated Smoke Alarm to stop an unwanted alarm (caused by cooking smoke, etc.). Removing batteries disables the alarm so it cannot sense smoke, and removes your protection. Instead open a window or fan the smoke away from the unit. The alarm will reset automatically.

If the unit alarms get everyone out of the house immediately.

WHAT TO DO IN CASE OF FIRE

Don’t panic; stay calm. Follow your family escape plan.

Get out of the house as quickly as possible. Don’t stop to get dressed or collect anything.

Feel doors with the back of your hand before opening them.

If a door is cool, open it slowly. Don’t open a hot door. Keep doors and windows closed, unless you must escape through them.

Cover your nose and mouth with a cloth (preferably damp). Take short, shallow breaths.

Meet at your planned meeting place outside your home, and do a head count to make sure everybody got out safely.

Call the Fire Department as soon as possible from outside. Give your address, then your name.

Never go back inside a burning building for any reason.

Contact your Fire Department for ideas on making your home safer.

Alarms have various limitations. See "General Limitations of Smoke/CO Alarms" for details.

USING THE SILENCE FEATURE

Never remove the batteries to quiet an unwanted alarm. Removing the batteries disables the alarm and removes your protection.

The Silence Feature is intended to temporarily silence the horn while you identify and correct the problem. Do not use the Silence Feature in emergency situations. It will not correct a CO problem or extinguish a fire.

To use the Silence Feature, press and hold the Test/Silence button on the cover of the Smoke/CO Alarm for 3 seconds.

When the Smoke Alarm is Silenced

When the CO Alarm is silenced

 

 

The Smoke Alarm will remain silent

The CO alarm will remain silent for

for 8 minutes, then return to normal

4 minutes.

operation.

After 4 minutes, if CO levels remain

 

If the smoke has not cleared–or con-

potentially dangerous the horn will

tinues to increase–the device will go

start sounding again.

back into alarm.

 

 

 

3

Image 3
Contents Table of Contents USER’S ManualIntroduction HOW to Install this Alarm InstallationWhere to Install this Alarm Where this Alarm should not be InstalledIf the Smoke Alarm Sounds If Your SMOKE/CO Alarm SoundsWhat to do FIRST-IDENTIFY the Type of Alarm If the CO Alarm SoundsWeekly Testing Regular MaintenanceWhat YOU Need to Know about CO HOW can I Protect MY Family from CO POISONING? Regulatory Information for SMOKE/CO AlarmsRegulatory Information for CO Alarms Regulatory Information for Smoke AlarmsMulti-Family or Mixed Occupant Residence General Limitations of SMOKE/CO AlarmsAbout Smoke Alarms Special Compliance ConsiderationsLimited Warranty Troubleshooting Guide

Carbon Monoxide Alarm specifications

The First Alert Carbon Monoxide Alarm is a leading device designed to protect households from the dangerous effects of carbon monoxide (CO) exposure. CO is a colorless, odorless gas that can lead to severe health problems and even fatalities if undetected. The First Alert CO alarm utilizes advanced technology to provide reliable performance, ensuring the safety of you and your loved ones.

One of the primary features of the First Alert Carbon Monoxide Alarm is its electrochemical sensing technology. This technology enhances the alarm's sensitivity to carbon monoxide, allowing for rapid detection of even low levels of CO. This sensitivity ensures that the alarm sounds promptly, giving occupants more time to react and evacuate or take necessary actions.

The alarm is equipped with a digital display that provides real-time updates on CO levels in the environment. This feature allows users to monitor the concentration of carbon monoxide in their homes, giving them insight into potential issues before the levels become dangerous. Moreover, the display often includes battery life indicators, ensuring users are always informed about the status of their device.

Another notable characteristic of the First Alert Carbon Monoxide Alarm is its compact and user-friendly design. The device can be easily installed in various locations throughout the home, such as bedrooms, hallways, or near fuel-burning appliances. With a simple setup process and clear user instructions, homeowners can ensure comprehensive coverage against CO exposure.

The alarm typically features a test/silence button, allowing users to periodically test the alarm’s functionality or silence it in non-emergency situations, such as when cooking. Additionally, many First Alert models come with a battery backup system, ensuring the alarm continues to function during power outages.

The First Alert Carbon Monoxide Alarm is also designed with the user experience in mind. It often includes a loud, penetrating alarm that meets or exceeds safety standards, ensuring that it captures attention even in the event of a potential emergency.

In conclusion, the First Alert Carbon Monoxide Alarm is a reliable, feature-rich device that enhances home safety against carbon monoxide. Its electrochemical sensing technology, real-time digital display, and user-friendly design make it an essential addition to any household, helping to protect families from the unseen dangers of this lethal gas.