Feedback LED Indicator:
The green Feedback LED is used to provide feedback to the User as buttons are pressed and the logger performs various commands. These responses include:
Command | Feedback LED Response |
Enable Unit | 2 blinks |
Stop Unit | 2 blinks |
5 blinks | |
Two Button Reset | 5 blinks |
System Initialization (3 button) | 10 blinks |
Memory Clear | ON continuously for 10 |
| seconds then OFF |
Executing Program Net | 1 blink every 10 seconds |
Status LED Indicator:
The green STATUS LED is merely a visual indicator provided for User specified application from within a Program Net. This LED can be programmed by the User to indicate Alarms and other operational feedback.
Alarm LED Indicators (2):
The ALARM LED’s labeled R1 and R2, provide visual indication of the state of the two programmable operation output relays included in the
ENABLE Button:
Pressing the ENABLE button initiates the execution of the current Program Net residing in
If the Feedback LED does not blink twice in response to a press, the unit may already be Enabled or may have been previously running in the Rotary Memory Mode.
Note that operation of the ENABLE button may be inhibited if the logger is programmed with in the Rotary Memory Logging mode. In this mode, only one logging session can be logged. To initiate another, the first session must be cleared from memory. This parameter is set within the Global icon during construction of a Program Net. Refer to the Master Icon Reference Appendix for details on the Global icon.
While enabled and executing a Program Net, the Feedback LED will blink every 10 seconds indicating operation.
Using the |