Manuals
/
Omega Vehicle Security
/
Power Tools
/
Welding System
Omega Vehicle Security
manual
Using the OMP-MODL
Models:
OMP-MODL
1
76
297
297
Download
297 pages
51.3 Kb
73
74
75
76
77
78
79
80
Merged File Characteristics
Install
Alarm LED Indicators
Password
Calculating Lead Wire Effects
Configured as outputs
Reset Button
Accessing the HyperNet Window
ML-BATT Battery Pack Module
RTC / Memory Backup Battery
Page 76
Image 76
3... I
NTERFACE
M
ODULES
N
OTES
3-52
U
SING
T
HE
OMP-MODL
Page 75
Page 77
Page 76
Image 76
Page 75
Page 77
Contents
OM-MODL
OMEGAnetSM On-Line Service Internet e-mail Info@omega.com
Introduction
OMP-MODL System `THE BIG PICTURE’
OMP-MNL VS OMP-MODL
Manual Overview
OMP-MODL System Base
Interface Modules
HyperWare Software
Interface Module
Additional Components
Features
Summary of Steps in Utilizing the OMP-MODL
Introduction Using the Modulogger
System Base Overview
Enclosure / Mounting
Top Plate
Bottom Plate / Mounting
User Interface Indicators and Buttons
Main Power Switch
MLCPU-1 Module
Overview
Feedback LED Indicator
Status LED Indicator
Alarm LED Indicators
Enable Button
Reset Button
Stop Button
Button System Initialization
RS-232 Serial Communications Port
OMP-MODL System Base
Terminal Strip Connections
MLCPU-1 Terminal Strip Connections end view
LOW Range High Range
TTL Alarm Output Terminal
RTC / Memory Backup Battery
MLAD-1 Module
Four Channel Analog Input terminals 1 through
Cold Junction Compensation terminals 13, 14
Chassis Ground terminals
General Purpose Digital Input terminals 17
OMP-MODL System Base Using the OMP-MODL
ModuLogger System Base Using the ModuLogger
Interface Modules
Handling
Installation
Separating Modules without bending connector pins
Feedback LED on MLCPU-1
Layer / Module Address Reference
Interface Module Operational Instructions
Using the OMP-MODL
Field Installation of the ML-BATT Module
ML-BATT Battery Pack Module
Field Replacement of Batteries
ML-CPU Module
Module Installation
Hardware Input Signal Configuration Switches
Module Layer Requirements / Limitations
Push Buttons
Next and Select
Display
Display Operation
Select
Display Menu Items
Memory and Continue Processing during setup
Date and Time
Return to TOP Menu
Status Lights
Using the OMP-MODL
DC Voltage
Thermocouple
MLIM-1 Four Channel Analog Interface Module
MLIM-1 Module Address Switches
DC Current
10 Example Address setting for Module Layer Position
Input
MLIM-1 Channel Configuration via Software
Input Overcurrent Fuses
Thermocouple Connection
MLIM-1 Thermocouple Application
Thermocouple Application Notes
Signal Connection all Ranges
MLIM-1 DC Voltage Application
Shielded Twisted Pair Line
Common Mode Input Range Considerations
Signal Connection all Current Ranges
MLIM-1 DC Current MA-LO Application
Application Notes DC Voltage Channels Channel Isolation
GND
Application Notes DC Current Channels Channel Isolation
Using the OMP-MODL
17 MLIM-2 Module Address Switch Bank
MLIM-2 Digital Interface Module Overview
Hardware Input Configuration Switches
Software Configuration of the MLIM-2
MLIM-2 Event Input Application
MLIM-2 Counter Input Application
Event / Counter Input Signal Connections
VD C
MLIM-2 Frequency Input Application
Frequency Signal Connection
Shielded Twisted Pair Lead
Voltage Current milliAmps
MLIM-2 Digital Output Application
Digital Output Signal Connections
25 MLIM-2 Digital output terminal strip connections
26 MLIM-4 Module Address Switches
MLIM-4 RTD / Resistance Interface Module Overview
Software Configuration of the MLIM-4
27 Example Address setting for Module Layer Position
MLIM-4 Input Signal Connection Methods
MLIM-4 RTD Input Application
MLIM-4 Thermistor Input Application
MLIM-4 Resistance Input Application
Wire Configuration
Calculating Lead Wire Effects
Wire Terminal Strip Connections
Wire Compensation Theory
As can be seen in the 3-Wire Wiring Diagram, each channel
Wire Configuration
Range Excitation Current
Using the OMP-MODL
31 MLIM-8 Module Address Switch Bank
MLIM-8 Digital I/O Interface Module Overview
Software Configuration of the MLIM-8
MLIM-8 Event Input Application
Event Input Signal Connections
Powered Signal Application
ConnectionsStrip Terminal8
Contact Closure Application
Voltage
MLIM-8 Digital Output Application
Current milliAmps
Configured as outputs
Terminal Strip
Using the OMP-MODL
MLIM-5 Pcmcia Memory Card Module
Configuration of the MLIM-5
Operation of the MLIM-5 and Pcmcia Memory Card
Using the OMP-MODL
MLIM-5-2400 Pcmcia and 2400B Modem Module
Configuration of the MLIM-5-2400
Telephone Line Connection
Hardware Configuration Switches
Operation of the MLIM-5-2400
Installation / Operation
MLIM-5-144 Pcmcia and 14.4K Baud Modem Module
Using the OMP-MODL
Interface Modules Using the Modulogger
Hyperware S Oftware Introduction
Software Overview
PC Requirements
Hyperware Installation
Upgrading Hyperware to a NEW Version
Hyperware Program Topology
User Interface
Hyperware S Oftware Introduction
Hypercomm S Erial Communications
Overview
HyperComm Connection via RS-232
RS-232 Hardware Connection
Establishing AN RS-232 Link
Establishing a Telephone Modem Link
Modem Hardware Configuration
Is the Omega Engineering supplied adapter used?
HyperComm Connection via Modem
Port
Baud
Redial
Phone
Modem
Using the OMP-MODL
Visual Communications VIA Hypercomm
HyperComm serial communication window connection established
Communication Techniques
Communication Icons and their Functions Enable Button Icon
Stop Button Icon
Unit Name and ID Query
Status Query
Reported information includes
Time Set
Program Net Transfer
Data Download
Probe Point Query
10 File Information comments entry dialog
Password
13 Password Configuration Dialog
Disabling Passwords
Using the OMP-MODL
Hypercomm C Ommunications Using the Modulogger
Pcmcia Card Configuration and USE
Pcmcia Card System Components
Software Configuration
Hardware Configuration
Pcmcia Card Expanded Memory Capacity Application
OMP-MODL Configuration
PC / External Pcmcia Drive Configuration
Connecting the PD-1 Drive
Pcmcia Card Transportable Data Application
Installing the CardTalk Drivers
DEVICEHIGH=C\CARDTALK\CTALKCS.EXE
Quick Test of the Pcmcia Drive Configuration
HyperWare Software Configuration
Transferring Data from the OMP-MODL to the PC
Pcmcia Card Usage with HyperWare
Transferring a Program Net from the PC to the OMP
Memory Card Handling / Maintenance
Formatting Pcmcia cards
Windows 95 Special Pcmcia Card Considerations
Pcmcia Miscellaneous
Battery Compartment Door Read Only Read and Write
Using the OMP-MODL
Pcmcia Card Configuration and USE Using the Modulogger
Hypernet I CON Based Programming
Example Program Net
Temperature sampling Program Net
AN Example Program NET
Accessing the HyperNet Window
Hypernet Development Window Features and Tools
Returning to the HyperComm Window
HyperNet Window Topology
HyperComm Access
Create New Net
Open Net and Save Net
Delete Icon or Connection Link
Program Net Icon Selection Bar
Program NET Construction
Icon Placement
Using Grids
To Develop a New Program Net
To Open an Existing Net for Editing
Icons
Changing Fonts
Icon Topology
Icon
Configuring Icons
11 Thermocouple input icon configuration Dialog box
Signal Types
Icon Assortment
Global Icon
Making Connections Between Icons
Adding Signal Connections Between Icons
Program Net Checklist
Modifying the Routing of Icon Connection Lines
Saving the Net
NET Performance
Program Net Performance Guidelines
Program Net Execution Speed
An Empirical Answer
Miscellaneous Program Net Performance Considerations
Input Icon Type Samples per Second One channel
Terminal Strip Wiring Printout
HyperNet Printout
Program NET Documentation
Program NET Upload to the OMP-MODL
Using the OMP-MODL
POST-PROCESSING of Collected Data
POST-PROCESSING Nets
Using the OMP-MODL
Entering the Post-Processing window
Constructing a Post-Processing Net
Opening a OMP-MODL Download File *.HLD
Reviewing File Information
Connecting Icons
Adding Icons
Other Post-Processing Net Development Options
Saving the Post-Processing Net
Options / Paths
Tarting a P -PROCESSING Ession
Viewing the Onverted D
Hyper LOT
File Merge Process
Merged File Characteristics
Merging of Download Files
OMP-MODL
Hyperplot G Raphic Data Display
Launching Hyperplot
From HyperComm
From Post-Processing Window
From a Post-Processing Net
Time Axis
Zooming
Menu Bar
File Open View
Save as Bitmap
Zoom Last
Cursor
Analyze View
Options Axis
HyperPlot Options / X-axis
Y-Axis configuration dialog
Help
Via Bitmap Files
Via the Windows Clipboard
Plotting Large Files with Hyperplot
Hyperplot Graphic Data Display
Hypertrack R EAL-TIME Data Display
10-1
Constructing a OMP-MODL Program NET for Hypertrack
10-2
Constructing a Hypertrack NET
Determining OMP-MODL Program Net Probes Information
10-3
10-4
Probe Points detected in the currently loaded Net Program
Building the HyperTrack Net Icons
Reading Probe Point icons from a Program Net on disk
10-5
Saving the HyperTrack Net
Other HyperTrack Net Development Options
10-6
HyperTrack Scrolling Display Window
Channel Display Order
Starting a Hypertrack Session
10-7
Data Buffer
HyperTrack Trending Display Window
Time Display Formats
Trending Configuration Dialog
10-9
Pausing a Hypertrack Session
Channel Ranges
Plot Period
Resuming After Pause
Stopping a Hypertrack Session
10-11
10-12
10-1
Appendices
11-1
11-2
Thermocouple Input Icon
Appendix a Master Icon Reference
11-3
11-4
CJC Cold Junction Compensation Input Icon
11-5
Supply Voltage Vbatt Input Icon System Base
11-6
DC-LO +/- 2VDC Full Scale Voltage Input Icon
11-7
11-8
DC-MED +/- 10 VDC Full Scale Voltage Input Icon
11-9
DC-HI +/- 30 VDC Full Scale Voltage Input Icon
11-10
MA-LO +/- 20 Madc Full Scale Current Input Icon
11-11
11-12
RTD Input Icon MLIM-4
11-13
11-14
Thermistor Input Icon MLIM-4
11-15
11-16
Resistance Input Icon MLIM-4
11-17
11-18
Event Input Icon Gpdi
11-19
11-20
Counter Input Icon Gpdi
11-21
11-22
Event Input Icon Digital I/O with MLIM-2
11-23
11-24
Counter Input Icon Digital I/O with MLIM-2
11-25
11-26
Frequency Input Icon Digital I/O with MLIM-2
11-27
11-28
Event Input Icon Digital I/O with MLIM-8
11-29
11-30
Digital Output Icon MLIM-8
11-31
Digital Alarm Output Icon System Base
11-32
Relay Alarm Output Icon
11-33
+5 Volt Output Icon System Base
11-34
Green LED Status Output Icon
11-35
LCD Message Output Icon
11-36
Digital Output Icon MLIM-2
11-37
Pager CALL-OUTICON
11-38
11-39
Probe Point Output Icon
11-40
11-41
Memory OMP-MODL Icon
11-42
11-43
Destination File Icon
11-44
REAL-TIME Scrolling Display Icon
11-45
REAL-TIME Trending Display Icon
11-46
Dialog Configuration Options
11-47
Delta Function Icon
11-48
11-49
Average Function Icon
11-50
11-51
11-52
Minimum Function Icon
11-53
11-54
Maximum Function Icon
11-55
11-56
SUM Function Icon
11-57
11-58
DUTY-CYCLE Function Icon
11-59
11-60
Time Integration Function Icon
11-61
11-62
Input Rate Timebase Units per
Math Function Icon
11-63
Function Syntax Explanation
11-64
TCJX,Y
11-65
11-66
Comparator Setpoint Function Icon
11-67
11-68
11-69
Constant Function Icon
11-70
11-71
Latch Function Icon
11-72
11-73
Logic Function Icon
11-74
Or Logic Function Icon
11-75
XOR Exclusive or Logic Function Icon
11-76
Not Inverter Logic Function Icon
11-77
Timed Counter Function Icon
11-78
11-79
UP Counter Function Icon
11-80
11-81
Sample Rate Clock Function Icon
11-82
11-83
11-84
WARM-UP Function Icon
11-85
11-86
START/STOP Clock Function Icon
11-87
11-88
11-89
Periodic Output Function Icon
11-90
11-91
Stop Logging Function Icon
11-92
11-93
11-94
Global Function Icon
11-95
11-96
11-97
Histogram Function Icon
11-98
11-99
Remote Control Function Icon
11-100
11-101
11-102
HAP Function Icon
11-103
11-104
Text Note Icon
11-105
11-106
Rate of Change Function Icon
11-107
11-108
Engine Oil Cooler Performance Test
Appendix B Example Program Nets
11-109
Hydraulic Pump Performance Test
11-110
11-111
High Speed Thermocouple Application
11-112
11-113
11-114
Path and File Description
Appendix C Hyperware File Listing
11-115
11-116
Page
Appendix D Changing the Clock / Memory Backup Battery
11-118
11-119
11-120
Appendix E Changing the OMP-MODL
11-121
11-122
Appendix F Filtering Options
ADC Input Filtering
50Hz / 60Hz Sofware Filtering
11-123
11-124
Appendix G Hypernet Theory of Operation
11-125
11-126
Appendix H Accessories
11-127
11-128
Appendix I RS-232 CABLE, PORT, Adapter
11-129
11-130
Appendix J Troubleshooting Tips
11-131
11-132
OMP-MODL may have a corrupted Program Net
Appendix K Modem Configuration Supplement
Local 2400 to Remote 2400 MDM-2400 Modem Option
Baud Rate
Local 2400 to Remote 14.4 MDM-14.4 Modem Option
Local 14.4 to Remote
Local 14.4 to Remote 14.4 MDM-14.4 Modem Option
Baud Rate 19,200
11-134
11-135
Top
Page
Image
Contents