Omega Vehicle Security OMP-MODL manual Event Input Signal Connections, ConnectionsStrip Terminal8

Models: OMP-MODL

1 297
Download 297 pages 51.3 Kb
Page 73
Image 73

ConnectionsStrip

Terminal8

-HLIM

V+

R1

A

B

COM

C

D

COM

E

F

COM

G

H

COM

Logger

Circuit Ground

3... INTERFACE MODULES

Current Limited Output Driver

Event Signal

Debounce RC

Software Controlled

Debounce Circuit

ML135

Figure 3... -32: Simplified schematic of MLIM-8 input/output channel

(single channel shown)

Event Input Signal Connections:

To utilize an MLIM-8 channel as an Event input, connect the input signal positive lead to an Input terminal (Chan A, B, C, D, E, F, G, or H) and the

 

 

 

A

 

B

C

D

Contact Closure Application

ChannelChannelChannelChannelCommon Common

 

Contact Closure

1

2

3

4

5

6

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ML058

Isolation from Relay contact closure

 

 

 

 

 

 

 

Powered Signal Application

 

 

 

 

 

 

 

TTL or CMOS

 

 

 

 

 

 

 

 

15VDC Max

12

Lamp

VDC

 

Figure 3... -33: Contact closure and Powered type Event signal input

USING THE OMP-MODL

3-49

Page 73
Image 73
Omega Vehicle Security OMP-MODL Event Input Signal Connections, ConnectionsStrip Terminal8, Contact Closure Application