11... APPENDIX A: MASTER ICON FILE REFERENCE
LCD MESSAGE OUTPUT ICON
FUNCTION:
User programmed messages can be displayed on the LCD (liquid crystal display) on the front panel of the
INPUTS:
Data/Logic Signal: Logic type. True input turns message ON. False input turns message display OFF. Optionally, use the Latch icon in front of the LCD Message icon to latch the message ON upon receipt of a momentary True input.
Update Clock: | None |
Enable:Processing of icon is allowed when Enable pin is unconnected or when connected and Enable signal is TRUE.
OUTPUTS:
Output Signal: Hardware output (to LCD display) only. No output terminal shown on icon for Program Net connections.
ICON CONFIGURATION DIALOG BOX:
CONFIGURATION OPTIONS:
Icon Name: Specify the label for the icon. This name will show directly under the icon within the Program Net.
First / Second Line Output: Two text boxes are provided for User entry of text to be displayed on the LCD when the Input is TRUE. Up to 16 characters can be entered on each line.
APPLICATION CONSIDERATIONS:
When the LCD icon is activated (ie its input is TRUE), the programmed message is displayed on the
| USING THE |