10... HYPERTRACK™ R EAL-TIME DATA DISPLAY

Saved HyperTrack Nets should only be used for real-time tracking with OMP-MODLs configured with Program Nets that contain matching Probe Point icons. If mismatched nets are used, channels may be incorrectly titled and displayed in incorrect sequence.

For example: A HyperTrack Net is developed and saved for use with a OMP-MODL Program Net that includes 3 Probe Point icons labeled A, B, and C. Accidently, the HyperTrack Net is used with a OMP-MODL running a Program Net that contains only 2 Probe Point icons labeled X and Y. The resulting HyperTrack Net data display will result in two channels labeled A (displaying X data) and B (displaying Y data) and a third channel labeled C that just displays 0.

To avoid this confusion, check the correlation between the HyperTrack Net and the OMP-MODL Program Net before Tracking.

STARTING A HYPERTRACK SESSION

Initiation of a HyperTrack session is handled from within the HyperTrack window. Before starting a session, the following conditions must be met:

The OMP-MODL must be programmed with a Program Net including Probe Point icons

A serial connection between the OMP-MODL and the PC must be established

A compatible HyperTrack Net must be loaded and displayed on the HyperTrack window of HyperWare

All File icons included within the HyperTrack Net must have filenames provided

The OMP-MODL must be Enabled

To start tracking, click on the Green Start button. Clicking on this button commands the connected OMP-MODL to start sending out the Probe Point icon values, which are in turn processed by the HyperTrack Net on the PC. The Scrolling Display window(s) will automatically open and begin displaying data. Any Destination File icons will create the specified filenames and begin recording to that file.

HyperTrack Scrolling Display Window

During real-time tracking, data from the signals connected to the Scrolling Display icon is displayed in a columnar format in the pop-up Scrolling Display window.

Channel Display Order

The order of display (left to right) of inputs is set by the order of connection of signals to the Scrolling Display icon. The top connection is displayed on the left and the bottom connection is displayed on the right.

Up to 8 channels can be displayed in the Scrolling Display window. Utilize the slide bar at the bottom of the window to view channels that are out of the window to the left or right.

USING THE OMP-MODL