11... APPENDIX A: MASTER ICON FILE REFERENCE

constant of approximately 50mS. Note that the use of Debounce will delay the actual input to output time by 50 to 200 mS.

FYI: Contact bounce is a phenomenon that occurs when a mechanical switch opens or closes. During switching, the physical electrical contacts inside the switch bounce against each other a number of times before they settle to their final state.

Depending on the duty cycle of the contact bounce, the OMP-MODL may count these bounces as events or transitions (count mode) resulting in technically accurate but undesired data. By enabling the debounce function, typical short duration contact bounce will be filtered out.

Output True when input is LOW / HIGH: Specify what the state of the input

signal is for the icon Output to be True. For example, if a switch is connected to the Event icon input, the User can then specify which state the switch should be in for a TRUE Output from the Event icon. Output True when input is LOW will result in an icon Output that is TRUE when the switch is closed. Output True when input is TRUE will result in an icon Output that is True when the switch is open.

11-20

USING THE OMP-MODL

Page 182
Image 182
Omega Vehicle Security OMP-MODL manual 11-20