11... APPENDIX A: MASTER ICON FILE REFERENCE

ICON CONFIGURATION DIALOG BOX:

CONFIGURATION OPTIONS:

Icon Name: Specify the label for the icon. This name will show directly under the icon within the Program Net.

Input Name: In this box, HyperNet displays the Output Name of the icon connected to this icon’s Input. The Output Name can be changed in the other icon’s dialog.

Output after __ Samples: Specify the number of input readings to analyze before outputting the maximum value in the group.

Output current Value upon disable: Check this box to force an output of the current Maximum Value at any time that the icon is disabled. If this box is not checked, upon receipt of a disable signal, the Maximum calculation will be momentarily suspended until the icon is re-enabled and no in-process value will be output.

For example, if a Maximum is to be calculated over 10 samples but only 7 have been analyzed and the icon is disabled, the 7 sample Maximum Value will be output and the Maximum Value detection will be suspended until re- enabled. Upon re-enable, the detection will continue and after 3 more samples are received, the 10 sample Maximum will be output (unless the following check box is checked)

Clear Sample Count and Value upon Enable: Check this box to force a reset of the Maximum Value as well as the Sample count used used for the calculation upon receipt of an Enable signal.

If this box is not checked, upon receipt of an Enable signal, the Maximum analysis will proceed from its suspended state (that it entered when it was disabled).

Units: Provides a text box for User entry of a units label that will be shown at the output from this icon.

Output Name: Specify the label for the Output. This name will show directly under the Output terminal within the Program Net.