11.. . APPENDIX A: MASTER ICON REFERENCE

RESISTANCE INPUT ICON (MLIM-4)

FUNCTION:

RTD, resistance, and thermistor signal inputs can all be handled with the MLIM-4. With the MLIM-4 installed in a OMP-MODL, these respective function icons become available for use in Program Nets.

As a Resistance input, the icon samples the resistance of the connected input and passes it along to the next icon. 2, 3, and 4-wire configurations are all supported.

This channel/icon can be changed to a thermistor or RTD input channel by selecting the

Change button.

INPUTS:

Hardware: No signal input shown on icon for Program Net connections.

Update: The input is sampled every time an Update command is received on the Update input and the Enable terminal is True.

Enable: Processing of the icon is allowed when Enable pin is unconnected or connected and the Enable signal is TRUE.

OUTPUTS:

Output Signal: Data type signal. The Units of the output are ohms.

ICON CONFIGURATION DIALOG BOX: