11.. . APPENDIX A: MASTER ICON REFERENCE
DIGITAL OUTPUT ICON (MLIM-2)
FUNCTION:
Four channels of Digital output are provided (along with 4 channels of Event / Counter/ and Frequency input) with the
The Digital Output icons provide software access to these digital outputs.
Refer to the Frequency, Counter and/or Event applications of the
INPUTS:
Data/Logic Signal: Logic type. True input turns hardware output ON. False input turns output OFF. Optionally, use the Latch icon in front of the Digital Output icon to latch the Output True upon receipt of a momentary True input.
Update Clock: | None |
Enable:Processing of icon is allowed when Enable pin is unconnected or connected and Enable signal is TRUE.
OUTPUTS:
Output Signal: Hardware output only. No output terminal shown on icon for Program Net connections.
ICON CONFIGURATION DIALOG BOX:
CONFIGURATION OPTIONS:
Icon Name: Specify the name for the channel. This name will show directly under the icon within the Program Net. If no name is User provided, the Backplane Port (1 to 6) and Channel (A to D) where the actual Interface Module channel is installed will be used for the name.
Input Name: In this box, HyperNet displays the Output Name of the icon connected to this icon’s Input. The Output Name can be changed in the other icon’s dialog.
USING THE |
|