11.. . APPENDIX A: MASTER ICON REFERENCE
TIME INTEGRATION FUNCTION ICON
FUNCTION:
Calculates the time integral of data type input over a User defined integration period. The Time Integral icon can only be used with DATA type inputs.
NOTE: For LOGIC type input time integration, refer to the
For example, the Integral icon can be used in a Net (see above) to determine the hourly flow total of oil through a pipe. The oil flow RATE is sampled every minute by a
INPUTS:
Data/Logic Signal: Data
Update Clock: Yes, specifies the time period over which the input signal is integrated
Enable:None
OUTPUTS:
Output Signal: Data type. The Integral icon updates its output with the new integral value after receiving an Update Command from the connected Update Clock.
USING THE |
|