11... APPENDIX C: HYPERWARE FILE LISTING
Hydraulic Pump Performance Test
The above Net is designed for collecting data from a hydraulic pump on a vehicle during periods of high fluid temperature operation only. Two thermocouple channels and a continually powered pressure transducer are sources of input signals.
After Enabling the Net, the inputs are sampled every 30 seconds. When the Tinlet temperature exceeds 160F (Comparator and Constant icons), data storage to memory is Enabled for all three parameters and the
The DC voltage from the pressure transducer is converted to PSI via the Math icon.
Instantaneous values for the two temperatures and pressure are accessible on the