Honeywell EC-P2 instruction manual Table of Contents

Page 5

 

Table of Contents

 

Introduction

4

1 System Description

7

System Specifications

8

2.1

Operating the Sensor

8

2.2 Changing the Target Gas using SMART-CELL Technology ..

9

2.3

Response Test

10

2.4

Sample Inlet Port

10

2.5

Response/Recovery Time

10

2.6

Interference Gases

11

2.7

Alarm Functions

11

2.8

Display Resolution

11

3 Maintenance

12

3.1

Periodic Maintenance

12

3.2

Sensor Life

12

3.3

Calibration

12

 

To Enter ZERO / SPAN Mode

13

 

Zero Calibration

13

 

Span Calibration

13

 

To Exit ZERO / SPAN Mode

13

3.4 Troubleshooting

13

4 Programming and Advanced Features

15

4.1

Alarm Setpoints, Functions

15

 

To Enter CAUT / WARN / ALRM Mode

15

 

Warning Setpoint

15

 

To Exit CAUT / WARN / ALRM Mode

15

 

To Enter CAUT / WARN / ALRM Mode

15

 

Warning Function

16

 

To Exit CAUT / WARN / ALRM Mode

16

4.2

Display Variables

16

 

To Enter AVG / BLANK Mode

16

 

AVG Variable

17

 

To Exit AVG / BLANK Mode

17

4.3 Sample Mode

17

 

Taking a sample

17

 

Programming sample mode variables

17

 

To Enter SAMP / MEAS / CLEAR Mode

17

 

SAMP Variable

18

 

To Exit SAMP / MEAS / CLEAR Mode

18

4.4

Data Logging

18

 

EC-P2 software installation:

18

Honeywell EC-P2 Instruction and Installation Manual

5

Image 5
Contents Honeywell EC-P2 Page Page Introduction Table of Contents Analog Output Basic Parts of the Honeywell EC-P2 Sensor System DescriptionOperating the Sensor System SpecificationsChanging the Target Gas using SMART-CELL Technology Sample Inlet Port Response/Recovery TimeResponse Test Interference Gases Alarm FunctionsDisplay Resolution Periodic Maintenance MaintenanceSensor Life CalibrationTo Enter Zero / Span Mode TroubleshootingTo Exit Zero / Span Mode Zero CalibrationCalibration of the Honeywell EC-P2 Sensor using a Bypass Tee Alarm Setpoints, Functions Programming and Advanced FeaturesTo Enter Caut / Warn / Alrm Mode To Exit Caut / Warn / Alrm ModeDisplay Variables To Enter AVG / Blank ModeSample Mode EC-P2 software installation To Exit Samp / Meas / Clear ModeData Logging Samp VariableWorking with the EC-P2 program Analog OutputTo Exit Range Mode Changing the full scale range on EC-P2 To Enter Range ModeAdjusting the Range Available SMART-CELLs Appendix aNH3 H2S NO2 SO2 Hcho SMART-CELL Cross-Sensitivity Table Interference GasesNone means there is no interference Exclusions Limited WarrantyHoneywell EC-P2 Instruction and Installation Manual Page Page Find out more Contact Honeywell Analytics Americas
Related manuals
Manual 17 pages 4.03 Kb

EC-P2 specifications

The Honeywell EC-P2 is a sophisticated and versatile product designed for enabling efficient monitoring and management of various building systems. This advanced device is particularly popular among facility managers and operational teams for its exceptional features and robust technology that enhance the overall functionality of building automation.

One of the standout features of the Honeywell EC-P2 is its dual communication capability. It integrates seamlessly with both BACnet and Modbus protocols, enabling effective interoperability within diverse building management systems. This flexibility allows users to connect various devices and sensors, creating a unified and streamlined infrastructure.

The EC-P2 is equipped with advanced sensor technology that provides real-time data on numerous environmental parameters. By accurately monitoring variables such as temperature, humidity, and air quality, the device plays a crucial role in optimizing indoor comfort and energy efficiency. This real-time monitoring helps facility managers make informed decisions and deploy strategies that reduce energy consumption and operating costs.

Another notable characteristic of the Honeywell EC-P2 is its user-friendly interface. The device comes with an intuitive display that provides easy access to key parameters and system statuses. Users can easily configure settings and troubleshoot any issues directly through the interface, minimizing downtime and improving operational efficiency.

In terms of expandability, the EC-P2 offers multiple I/O options, making it versatile enough to handle various applications. This expandability allows for integration with additional sensors and control devices, ensuring that the system can grow alongside changing operational needs.

Notably, the EC-P2 is designed with security in mind. It incorporates robust security measures to safeguard data and ensure safe communication over the network. This focus on security is increasingly important in today’s connected environments, where cybersecurity threats pose significant risks.

Finally, the Honeywell EC-P2 stands out for its reliability and durability. Built with quality components and rigorous testing standards, it is engineered to function effectively in demanding environments. Whether used in commercial buildings, industrial settings, or educational institutions, the EC-P2 is a trusted solution for modern building management needs.

With its advanced features, wide-ranging compatibility, and focus on efficiency and security, the Honeywell EC-P2 is a pivotal component in creating intelligent, responsive, and sustainable building environments. Its integration capabilities and user-centric design make it an invaluable tool for optimizing operational performance in today's fast-evolving technological landscape.