Testing the Electronics

You should test the alarm once a week, following the directions listed below. If at any time you test the alarm and it does not perform as described below, have it replaced immediately. See “How to know if your alarm is malfunctioning” on page 17 for a description of the characteris- tics of a malfunctioning alarm and what you should do if a malfunction occurs.

Observe the alarm weekly to make sure the red dot is blink- ing, indicating normal operation.

If the dot is not blinking, unplug the alarm, then plug it in

 

again. This will clear the alarm for restart. If the dot does

Blinking Dot

not resume blinking, your alarm may be malfunctioning.

 

To test the alarm, press the Test/Reset button. If the unit is operating properly, you should notice the following:

The display shows three eights, and then shows a num- ber (usually around 200). You will then hear 4 quick beeps

– followed by 5 seconds of silence – followed by 4 quick beeps. The unit will then show the three eights for several seconds. It will then return to monitoring for carbon monoxide.

Familiarize yourself and household members with the alarm pattern described above. In the event of a CO incident, this pattern will continue to repeat as long as CO is present.

NOTE: Pressing the Test/Reset button tests the functions of the alarm’s internal components, circuitry and micro-computer. YOU DO NOT NEED TO PRESS THE TEST BUTTON TO TAKE A CO READING. CO read- ings are automatically shown on the alarm’s digital display. If the alarm shows zero (0), then no measurable amount of CO has been sensed by the alarm within the past 15 seconds.

16

Image 20
Contents Carbon Monoxide Table of Contents Page Quick Set Up Guide Setting up your alarm for first time operationQuick Set Up Guide Introduction Features Bryant CO Alarm front viewDigital Display Rear view with back door removed Pull-Out Transformer/AdapterWhat Carbon Monoxide Alarms Can and Cannot Do Recommended Locations InstallationWhere to Install Your CO Alarm Where Not to Install Your CO Alarm AT Least 5 feet away from applianceHow to Install Your Alarm Direct Plug AlarmTo install Avoid the followingWall Mounted Alarm Plug the alarm into an unswitched wall socketIf the outlet is mounted horizontally sideways To rotate the adapterTable Top Alarm WallBattery Installation Battery Installation and OperationBattery Backup Operation Battery Backup OperationBattery Back-up Operation in Low Battery Lb Condition Battery Back-up Operation inTrouble Alarm ConditionPage Normal Operating Characteristics OperationTesting the Electronics If the alarm malfunctions Malfunction Signal Group 1 Component FailureMalfunction Signal Group 2 Microprocessor Failure What to do if you’re not sureStart and some cleaning agents How to Care for Your AlarmAlarm from the electrical outlet before vacuuming To Reset the Peak Level Memory… Peak Level MemoryHome Safety Tips What You Can Do Carbon MonoxideWhat You Should Not Do Never use a gas range, oven, or clothes dryer for heatingUnderstand the Effects of Carbon Monoxide Exposure Loose or disconnected vent/chimney, fireplace or applianceClues You Cannot See What To Do When the Alarm Sounds Common Mild Exposure SymptomsCommon Medium Exposure Symptoms Common Extreme Exposure SymptomsTion If alarm signal sounds 4 quick chirps, 5 seconds offCall your emergency services Specifications Replacement of Alarm SpecificationsHow the Unit Determines When to Alarm AC and DC Start Up, Alarm and Error Operation Display ReadingsAC Powered in Normal Stand-by Operation DC Powered in Battery Backup OperationLi-Ion Battery Handling Precautions Detect COBattery Storage When Detached From the Alarm Limited Warranty For Warranty Service Please send products and all other correspondence to