12. TECHNICAL SPECIFICATIONS

 

 

Operating Voltage

: 230±10% VAC, 50Hz

Power

:

1 Watt (60 mA)

Power on Indicator

:

Green Light

Sensor

:

Electrochemical Sensor

CO Sensitivity

: Meets BS EN 50291: 2001.

 

 

Unit operates as per Table B (on page 8).

Electrical Safety

: Complies with relevant sections of EN 60335-1: 1994

Electromagnetic

: Complies with BS EN 50270

Compatibility

 

 

Test/Hush Button

: Checks electronics and horn.

 

 

When the unit is alarming, after sensing CO, pressing the Test/Hush button will immediately stop

 

 

the horn (the red light will continue to flash). If CO is still present the red light and the horn will turn

 

 

on again after about 4 minutes. The unit can only be silenced once during a CO incident. At 300

 

 

ppm CO the unit cannot be silenced. (With interconnected units, the Hush only works on the alarm

 

 

sensing CO).

Fast CO Test Mode

: Pressing the Test/Hush button also causes the unit to check for CO 4

 

 

seconds later to facilitate testing in CO gas. It gives 3 beeps and the red light

 

 

flashes to indicate the CO level if CO is sensed and then resets.

28

Image 28
Contents Mains Powered Carbon Monoxide Alarms B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Contents Important Information What to do When the Alarm Sounds What is Carbon Monoxide ? Symptoms of Carbon Monoxide PoisoningCarbon Monoxide the Silent Killer High levels of CO in a house can be caused byInhalation Time approx and Symptoms Developed Table a Effects of Carbon Monoxide PoisoningWhat Happens When Your CO Alarm Detects Carbon Monoxide ? Never Ignore the Alarm CO Alarm MemoryIdeally a Carbon Monoxide CO Alarm should be Installed Alarm PositioningUnsuitable Locations B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Location in room with a fuel burning appliance Location in rooms with Installation Alarm InstallationInstallation Procedure B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Surface Wiring Interconnecting Testing Testing with Carbon Monoxide Maintenance HOW to Distinguish Between CO Alarm & Smoke Alarm WarningsDo not paint the CO Alarm HOW to Disconnect and Remove the Alarm Sensor Module ReplacementLimitations of CO Alarms HOW to Protect Your Family B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Getting Your CO Alarm Serviced Five Year GuaranteeTechnical Specifications B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Alarm does not Work When the Test Button is Pressed TroubleshootingAlarm Beeps and Amber Light Flashes Every 40 Seconds Alarm Sounds for no Apparent Reason Test/Hush Button does not Silence AlarmsAccessories CheckB16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Ei Electronics

Ei261ENRC, Ei261DENRC specifications

The Aico Ei261DENRC and Ei261ENRC are advanced smoke alarms designed specifically to enhance home safety while providing numerous innovative features. Both models incorporate cutting-edge technologies, ensuring maximum effectiveness and reliability in detecting smoke and fire.

The Ei261DENRC is the versatile model that includes a built-in radio interlink feature. This means that when one alarm detects smoke or an increase in temperature, all interconnected units activate simultaneously. As a result, occupants throughout the home are alerted, regardless of their location. This interconnected technology is crucial for large homes or those with multiple levels, as it significantly increases the likelihood that residents will hear the alarm, especially if they are asleep.

In contrast, the Ei261ENRC model does not have the interlink functionality but still boasts a range of important features. Both models utilize a unique high-performance optical sensing technology, which helps in accurately detecting slow-burning fires, commonly associated with smoldering materials. This feature minimizes false alarms, providing peace of mind for homeowners who are often concerned about nuisance activations.

Another standout characteristic of the Ei261DENRC and Ei261ENRC is their long-lasting battery life. Equipped with a lithium battery that can last up to 10 years, users can enjoy the convenience of reduced maintenance. The battery is designed to power the alarm throughout its lifespan, meaning there won’t be any need for frequent replacements.

Moreover, both alarms come with a unique ‘Smart Silence’ feature, allowing homeowners to temporarily silence the alarm with the press of a button during cooking or when dealing with minor smoke occurrences that do not pose a danger. This intelligent feature helps in preventing unnecessary distress caused by false alarms.

Furthermore, these models are designed with a user-friendly installation process in mind, with clear guidelines provided for mounting and setup. Both the Ei261DENRC and Ei261ENRC are compliant with the latest safety standards, ensuring optimal performance and reliability.

Overall, the Aico Ei261DENRC and Ei261ENRC smoke alarms represent an essential investment for any household prioritizing safety and reliability. Their integration of innovative technologies and user-friendly features make them a must-have for modern home protection.