NEVER IGNORE THE ALARM

Pre-Alarm:When the alarm detects over 50ppm CO the red light flashes every 2 seconds. This helps locate CO leaks as the unit gives an indication straight away (without this feature the CO level would need to be at 50ppm CO for 90 minutes for the horn to sound). Note the Pre-Alarm signal may be triggered by CO coming for example, from cooking with gas, from car engines or from nearby barbecues. This is usually not a concern unless the Pre-Alarm signal persists until the alarm sounds and the CO source is unknown.

Note: The CO Alarm may sound if cigarette smoke is blown into it, or aerosols are released nearby.

2.4 CO ALARM MEMORY

When the Test button is pressed the horn will sound, and the red light will only flash if the unit has previously detected CO and been in alarm. The flash rate indicates the level of CO detected as below:-

-Red light is Off – No CO detected since reset or power up.

-Red light flashes 2 times (in 2 seconds) every 40 seconds - 50 ppm CO detected for approximately 90 minutes since reset or power-up.

-Red light flashes 4 times (in 2 seconds) every 40 seconds - 100 ppm CO detected for approximately 40 minutes since reset or power-up.

-Red light flashes 8 times (in 2 seconds) every 40 seconds - 300 ppm CO detected for approximately 3 minutes.

When the Test button is held, the digital display on the Ei261DENRC model shows the previous peak reading. This tells you if the unit has detected CO in your absence and helps to detect and locate leaks, monitor premises etc.

Reset Memory by holding down the Test button for over 20 seconds until the red light stops flashing. Cover the horn with a cloth to muffle the alarm during this time.

Please note that the memory will also be reset when the unit is removed from the mounting plate.

9

Image 9
Contents Mains Powered Carbon Monoxide Alarms B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Contents Important Information What to do When the Alarm Sounds Symptoms of Carbon Monoxide Poisoning What is Carbon Monoxide ?Carbon Monoxide the Silent Killer High levels of CO in a house can be caused byTable a Effects of Carbon Monoxide Poisoning Inhalation Time approx and Symptoms DevelopedWhat Happens When Your CO Alarm Detects Carbon Monoxide ? CO Alarm Memory Never Ignore the AlarmAlarm Positioning Ideally a Carbon Monoxide CO Alarm should be InstalledUnsuitable Locations B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Location in room with a fuel burning appliance Location in rooms with Alarm Installation InstallationInstallation Procedure B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Surface Wiring Interconnecting Testing Testing with Carbon Monoxide HOW to Distinguish Between CO Alarm & Smoke Alarm Warnings MaintenanceDo not paint the CO Alarm Sensor Module Replacement HOW to Disconnect and Remove the AlarmLimitations of CO Alarms HOW to Protect Your Family B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Five Year Guarantee Getting Your CO Alarm ServicedTechnical Specifications B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Troubleshooting Alarm does not Work When the Test Button is PressedAlarm Beeps and Amber Light Flashes Every 40 Seconds Test/Hush Button does not Silence Alarms Alarm Sounds for no Apparent ReasonCheck AccessoriesB16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Ei Electronics

Ei261ENRC, Ei261DENRC specifications

The Aico Ei261DENRC and Ei261ENRC are advanced smoke alarms designed specifically to enhance home safety while providing numerous innovative features. Both models incorporate cutting-edge technologies, ensuring maximum effectiveness and reliability in detecting smoke and fire.

The Ei261DENRC is the versatile model that includes a built-in radio interlink feature. This means that when one alarm detects smoke or an increase in temperature, all interconnected units activate simultaneously. As a result, occupants throughout the home are alerted, regardless of their location. This interconnected technology is crucial for large homes or those with multiple levels, as it significantly increases the likelihood that residents will hear the alarm, especially if they are asleep.

In contrast, the Ei261ENRC model does not have the interlink functionality but still boasts a range of important features. Both models utilize a unique high-performance optical sensing technology, which helps in accurately detecting slow-burning fires, commonly associated with smoldering materials. This feature minimizes false alarms, providing peace of mind for homeowners who are often concerned about nuisance activations.

Another standout characteristic of the Ei261DENRC and Ei261ENRC is their long-lasting battery life. Equipped with a lithium battery that can last up to 10 years, users can enjoy the convenience of reduced maintenance. The battery is designed to power the alarm throughout its lifespan, meaning there won’t be any need for frequent replacements.

Moreover, both alarms come with a unique ‘Smart Silence’ feature, allowing homeowners to temporarily silence the alarm with the press of a button during cooking or when dealing with minor smoke occurrences that do not pose a danger. This intelligent feature helps in preventing unnecessary distress caused by false alarms.

Furthermore, these models are designed with a user-friendly installation process in mind, with clear guidelines provided for mounting and setup. Both the Ei261DENRC and Ei261ENRC are compliant with the latest safety standards, ensuring optimal performance and reliability.

Overall, the Aico Ei261DENRC and Ei261ENRC smoke alarms represent an essential investment for any household prioritizing safety and reliability. Their integration of innovative technologies and user-friendly features make them a must-have for modern home protection.