Operating your dehumidifier

Continuous On.

 

 

 

4Hr. On/Off

High

HUMIDITY

BUCKET

FULL

 

 

CONTROL

2Hr. On/Off

Low

 

 

 

TIMER

FAN

 

POWER

SPEED

 

 

 

 

CONTROL PANEL

The dehumidifier control panel contains: Bucket Full Indicator, Humidity Indicator, Power Control, Humidity Control, Fan Speed and Timer Control.

Bucket Full indicator ---This light glows when the water bucket is full and needs to be emptied. Power --- Operation starts when this button is pressed and stops when the button is pressed again. Humidity Control --- This button controls the humidity in the room.

: To raise the humidity setting

: To lower the humidity setting

The humidity setting can be set to a permanent "On" setting or to a specific humidity setting between 35% and 70%

in 5% increments.

"On" setting - dehumidifier runs continuously regardless of humidity condition.

35% - 70% setting - dehumidifier shuts on and off according to surrounding humidity conditions. Fan Speed --- This controls the speed of the airflow.

High: Fan speed is set to high.

Low: Fan speed is set to low.

When Fan Speed button is pressed, the fan speed mode is changed. Energy Timer --- Press this button to select type of operation.

Select Constantly On for uninterrupted operation.

Select either 2 or 4 Hr. On/Off for cycled operation:

The unit will operate for 2 or 4 hours, and then shut off completely for 2 or 4 hours. The cycle repeats until you change the setting.

When Energy Timer button is pressed, the Timer indicator lights shift as follows: Continuous On 2 Hr. On/Off 4 Hr. On/Off Continuous On.

Auto Restart --- Once power is restored after a power failure, the unit returns to its previous operation setting. The fan turns on immediately but, humidity control starts after a 2 minute delay.

TO OPERATE THE DEHUMIDIFIER:

1.Plug the power cord into an electrical outlet. Press the power button.

2.Set the humidity Control to "On" or to a specific humidity level between "35% RH(Relative Humidity) and 70%RH(Relative Humidity)" for normal operation.

If you need drier air, press the Humidity Control button.

If you need less moister air, press the Humidity Control button.

3.Press the Power button to stop the unit manually.

4.Press the Timer button to set the amount of time you want the unit to run. At the end of that time, the unit will shut off.

The Timer can be set for : Continuous On, 4 hours or 2 hours.

5.If you want to control the speed of airflow, press Fan Speed button. Each time that the Fan Speed button is pressed, the fan speed mode is shifted: High Low High

Note: Be careful not to lose the water bucket.

This dehumidifier doesn't run if the water bucket is not installed properly.

6

Image 6
Contents Dehumidifier For Your Records It could cause electrical shock or fire Safety PrecautionsRead all instruction before using It could cause fire or product damage hazardWhen the unit is to be cleaned, switch it off Dehumidifier must beFeatures Operating InstructionsElectrical requirements To raise the humidity setting To lower the humidity setting Operating your dehumidifierAutomatic shut off Disposing of collected waterCleaning of bucket Installation InstructionsInstalling the dehumidifier properly Choosing the proper location for your dehumidifierCare and Maintenance Do not use bleach or abrasivesAbove Troubleshooting Tips Does not startGoldstar Dehumidifier Limited Warranty USA No A20315D

DH30E, DH40E, DH50E, DH50EL, DH65E, DH65EL, DH70EL, DH50EL DH65E, DH65EL DH70EL specifications

Goldstar, a prominent name in the world of HVAC systems, has made waves with its range of dehumidifiers including the DH50EL, DH65E, DH65EL, DH70EL, DH30E, DH40E, and DH50E models. These units are designed to enhance indoor air quality by efficiently removing excess moisture, thereby preventing mold growth and improving comfort in various environments.

The DH50EL serves as a cornerstone of the lineup, featuring an impressive moisture removal capacity of up to 50 pints per day. Its energy-efficient operation is complemented by a user-friendly digital control panel, allowing for precise humidity settings. Additionally, the automatic humidistat detects moisture levels in the air, adjusting operation accordingly to maintain desired conditions.

On the other hand, the DH65E and the DH65EL models up the ante with a capacity of 65 pints per day, ideal for larger spaces or extremely humid conditions. Both units utilize innovative technologies such as a high-efficiency compressor and an advanced air filtration system that traps dust and allergens, promoting cleaner air. The DH65EL also introduces a built-in pump, enabling continuous drainage for uninterrupted operation—perfect for basements or places prone to high humidity.

The DH70EL, with its robust capacity of 70 pints, stands out for its enhanced moisture removal features combined with noise-reduction technology, making it suitable for residential and commercial applications where quiet operation is paramount.

The DH30E and DH40E models are tailored for smaller spaces, with moisture removal capacities of 30 and 40 pints per day, respectively. They are compact yet powerful, making them perfect for bathrooms, laundry rooms, and small basements. These units maintain the same energy-efficient design and user-friendly control features as their larger counterparts.

Lastly, the DH50E continues to offer a balanced approach with its 50-pint capacity, ensuring effective moisture removal for medium-sized areas. With a sturdy design and durable build, these Goldstar dehumidifiers are not only functional but are built to last, standing up to rigorous usage in various environments.

In summary, Goldstar’s lineup of dehumidifiers comes packed with technology and features that cater to diverse needs, from energy efficiency and automated controls to continuous drainage options. These characteristics make them a reliable choice for anyone looking to improve air quality and reduce humidity levels in their homes or businesses.