Tr o u b l e s h o o t i n g
Check the following points before calling your local authorised Service Centre.
Problem | Cause | Solution |
|
|
|
The appliance is operating | •filter clogged | •clean the filter |
in dehumidification mode | •the temperature or humi- | •in certain conditions, it is |
(indicator light on), but the | dity of the room is too low | normal for the appliance |
humidity does not decrease |
| not to dehumidify (in these |
|
| cases the room being |
|
| dehumidified should also |
|
| be heated) |
| •the room is too large |
|
| •too many sources of humi- |
|
| dity in room (boiling pots |
|
| etc.) | •decrease the humidity set |
| •humidistat set too high | |
| point | |
|
| |
|
|
|
The appliance does not | •the appliance’s safety devi- | •wait for 3 minutes |
work for around 3 minutes | ce has been activated |
|
when restarted |
|
|
|
|
|
The display shows “Ft” | •the tank is missing | •position the tank |
| •the tank is full | •empty the tank |
| •the tank is in the wrong | •position the tank correctly |
| position |
|
The display shows “Df” | •the temperature in the room | •increase the ambient tem- |
| is too low | perature |
The display shows “fp” | •one of the sensors on the | •call the Service Centre |
| appliance is faulty |
|
|
|
|
|
|
|