PARTS IDENTIFICATION (Shown, below)
Touchpad temperature controls
OPERATING INSTRUCTIONS
GETTING STARTED
PLACEMENT:
Left side
Duct D (Cold outlet)
Duct B (Heat outlet)
For cooling or heating, place at least one EB1400 per room.
1. | Place the unit on a level surface. |
2. | Make sure the System switch is set to Off then plug power |
| cord into a standard 115v grounded outlet. |
3. | Set the digital temperature controls needed to function |
| (see below). |
Condenser
Front filter (Inlet)
Drain Hose
pocketBack housing (filter set located inside)
Right side
Wheel casters | Rotomolded |
| shell |
Front and Right Side View
Touchpad temperature controls
Duct A (Heat inlet back
of unit)Rotomolded shell
Cord pocket
Left side
Wheel casters
Back and Left Side View
4. Check for proper operation before leaving the unit |
unattended. Do not move or carry the EB1400 when it is |
running or plugged in. |
OPERATING RANGE
Recommended operating range is between 60° – 115° F. The EB 1400 will not function properly when operating in environment with temperatures outside this range.
CYCLE TIMES AND COMPRESSOR PROTECTION
The EB1400 thermostat includes an automatic compressor protection feature to avoid potential damage to the cooling system from short cycling. This thermostat automatically provides a
Important Notes:
•If unit loses power or gets unplugged during operation, operator MUST wait 5 minutes before plugging unit back in or risk damaging the compressor or tripping the circuit breaker in the facility.
•Always turn the System switch to OFF before unplugging.
•If the System setting is adjusted during operation the unit will automatically delay 5 minutes before
•When switching unit from cooling to heating or heating to cooling operator must adjust setpoint temperature.
TESTING AND PROGRAMMING THERMOSTAT
DIGITAL CONTROLS
Digital screen
Reset
Up | Down |
|
|
Fan
On
Cool | Off | Heat | Auto |
2 |