Aprilaire 60 & 62 Route the Wire from Control to Sensor, Attach Sensor Wire to Humidifier Control

Page 7

STEP 8: Route the Wire from Control to Sensor

Run wire to the outdoor temperature sensor. Sensor is not affected by lead lengths less than 300 feet.

CAUTION

Do not run outdoor temperature sensor alongside wires carrying high voltage (120 VAC or higher).

Secure the sensor bracket with a #8 screw.

STEP 9: Attach Sensor Wire to Humidifier Control

Strip wire 1/4 inch, and insert the wires from the Sensor into the terminals labeled “ODT” on the Humidifier Control. See Figure H for location of terminals.

Figure H

90-1219B

BLOWER ACTIVATION

Set the Blower Activation Switch to “ON” to allow the Humidifier Control to activatethe furnacefan for additionalhumidification. This may be requiredif the humidifieris mountedon a heat pump or a furnace with short run cycles.

When the Blower Activation switch is “ON”, the Humidifier Control will turn on the HVAC blower when humidity is required. In the “OFF” position, the humidifier will only operate if humidity is required and the HVAC system is operating.

When the Blower Activation switch is “ON”, the Humidifier Control may periodically turn the HVAC blower on to sample the humidity of the air.

Installing the Humidifier Control for Manual Operation

If it is not feasible to install the Outdoor Temperature Sensor, the Humidifier Control can be operated in Manual Mode.

1.Position the Mode Switch in the “MAN” position. Manual indicator “M” will be displayed.

2.Apply the Manual Mode Label to the cover, aligning the sticker and knob holes.

Figure J

90-1236B

12

13

Image 7
Contents Automatic Digital HumidifierControl Model 60 Table of Contents Disassemble the Humidifier Control InstallationCheck the Change Water Panel IndicatorSetting Unpack the Humidifier Control CartonFigure C Determine Location for Humidifier Control and Mount ControlFigure E Digital Humidifier Control 24V Terminals Locate Existing Access Hole to Outside Determine Location for Outdoor Temperature SensorAlternate Location for Outdoor Temperature Sensor Attach Sensor Wire to Humidifier Control Route the Wire from Control to SensorSecure the sensor bracket with a #8 screw Minimum VA required is 2.0 VA Wiring Description90-1511 System Checkout Setting the Humidifier ControlBlower Activation Test Troubleshooting Guide Figure M Humidifier does not operate in Test/Reset modeYellow Change Water Panel light is blinking see Figure M Humidifier operates only in Test/Reset modeHumidifier operates constantly Research Products Corporation

60 & 62 specifications

Aprilaire models 60 and 62 are advanced dehumidifiers designed to enhance indoor air quality by effectively controlling humidity levels. These units are particularly suitable for homes in regions where excess moisture can lead to mold growth, structural damage, and discomfort.

Both the Aprilaire 60 and 62 feature a robust moisture removal system, capable of extracting up to 70 pints of moisture per day, depending on the model and conditions. This level of capacity ensures that even in significant humidity scenarios, your indoor environment remains comfortable and healthy.

One of the standout features of these dehumidifiers is their efficiency. The models utilize an Energy Star rating, which indicates they consume less energy while delivering optimal performance. This not only translates to reduced energy bills but also a lower environmental impact compared to less efficient units.

The technology used in Aprilaire dehumidifiers incorporates a built-in humidity control system. This allows users to set the desired humidity level, ensuring that the unit operates only when necessary. This automatic operation can prevent over-drying and maintain consistent humidity, which is crucial for both comfort and health.

Additionally, both models are designed with user-friendly interfaces. They come equipped with digital displays showcasing real-time humidity levels, allowing homeowners to monitor conditions effortlessly. Furthermore, they feature continuous drainage options, meaning that they can be connected to a drainage system to eliminate the hassle of manual water removal.

The Aprilaire 60 and 62 also boast a durable design, built to withstand the rigors of regular use. Their compact size makes them easy to position in a variety of home settings, whether in basements, crawl spaces, or other areas prone to humidity buildup.

In summary, the Aprilaire 60 and 62 dehumidifiers represent cutting-edge technology in humidity control. With high moisture extraction capabilities, energy efficiency, and user-friendly operation, they are ideal solutions for maintaining an optimal home environment. Homeowners seeking a reliable and effective way to manage humidity levels will find these models to be an excellent investment for ensuring comfort and protecting their living spaces from moisture-related issues.